background image

08/2017

 

 

 

 

Maintenance intervals

WARNING

Injuries and damage caused by 

improper or insufficient maintenance.

Component

500 h / 6 months

2000 h / 1 Y

ear

5000 h / 5 Y

ears

10000 h / 10 Y

ears

Activity

Electronic 

starters

X

Inspect and replace 

as necessary

X

Replace

Acrylic panes

X

Inspect and replace 

as necessary

X

Replace

Sleeve of the 

door cable 

entry

X

Inspect and replace 

as necessary

Chassis and 

associated 

fasteners

X

Inspect and replace 

as necessary

X

Replace

Wiring and 

associated 

plugs / terminal 

connections

X

Inspect and replace 

as necessary

X

Replace

Starter

decorative 

lighting

X

Replace

Electrolytic 

capacitors

X

Inspect and replace 

as necessary

X

Replace

Conductors

X

Inspect and replace 

as necessary

X

Replace

2.3

Component

After appr

ox. 250 

operating hours

After appr

ox. 500 

operating hours

After appr

ox. 1000 

operating hours

Activity

Tubes

X

Replace

aquaCool 

nozzles

X

Inspect and replace 

as necessary

X

Replace

Additional maintenance intervals

Yearly 
maintenance

Inspect the tanning device by a KBL autho-

rized representative every 12 months from 

date of the last inspection.

10 Years service

If the tanning device is in use for longer than 

10 years, it must be completely overhauled 

by qualified, trained and authorized service 

technician.

Start up if,

the tanning device 

has not been used 

for a longer period 

of time.

Inspect the tanning device by qualified, 

trained and authorized service technician, 

before being put back into operation again.

Summary of Contents for pureEnergy T230 W

Page 1: ... the maintenance status of their tanning device In case of questions contact our service representative 1 General information Definitions Qualified trainedandauthorizedservicetechnician Qualified staff who have been trained and autho rized by the manufacturer for assembly and main tenance work with specific devices Staff People who are responsible for the operation cleaning and disinfection as wel...

Page 2: ...ning device The electrical installation shall have a freely acces sible all pole disconnecting device Master switch with clearly labeled On Off settings e g 0 and I or additional indicator light fitted externally on the site side Training of staff The studio operator is obligated to train his staff and to instruct them in the established legal and accident prevention regulations He must ensure tha...

Page 3: ... and replace as necessary X Replace Conductors X Inspect and replace as necessary X Replace 2 3 Component After approx 250 operating hours After approx 500 operating hours After approx 1000 operating hours Activity Tubes X Replace aquaCool nozzles X Inspect and replace as necessary X Replace Additional maintenance intervals Yearly maintenance Inspect the tanning device by a KBL autho rized represe...

Page 4: ...ERSIONS e g AUGUST 2013 Operating Instructions BA_TpureEnergy_US Date x x Item no Assembly Instructions MA_TpureEnergy_US Date x x Item no If not please contact KBL AG Ringstraße 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 94 26 66 e mail customerservice kbl de Establish an accurate record keeping system for the maintenance reports Ensure that all maintenance periods have been ful ly c...

Page 5: ...de and outside of the tanning device is cleaned and free from dust fluff or objects Check the correct position of the plugs on the top of the rear of the appliance after each cleaning Insufficient cleaning results in overheating This can lead to damage the tanning device Approved UV tubes installed Make sure that the correct UV tubes are installed Only replace UV low pressure lamps with the origin...

Page 6: ...he tanning device may only be carried out by qualified trained and authorized service technician Faulty wiring can lead to electrical overstress and as a result damage the tanning device 3 1 Approved starters installed Make sure that the correct starters are installed and make sure that they are properly seated in their sockets Use only OEM spare parts Solar ÖKO82 4 230W Single 200 250 Vac 50 60 H...

Page 7: ...re properly installed into the terminals Test the conductors with a pincer for their tight fit Use only OEM spare parts Electronicon E12 E43 404500 MKP 45 F 5 280V 50 60Hz KBL item no 3200285000 KBL approved alternative Ducati Series 4 16 31 96 93 MKP 45 F 5 280V 50 60Hz The use of unsuitable capacitors can lead to elec trical overstress and as a result damage the tan ning device ...

Page 8: ... X 6 X 4 Positions from inside X 15L X 5 X 2 X 1 X 12 12A X 4 X 6 X 7 X 15R Back panel Attention Professional replacement of plug socket is conducted from inside the tanning device Under no circumstances pull the wire harness out of the socket from outside This may cause a reduction of the contact quality and could lead to electrical overstress ...

Page 9: ...cating electrical overstress Check the connector and socket inte rior for signs of electrical overstress Disconnect all connectors If there are signs of electrical overstress replace the affected connectors immediately If the connecting cables show signs of electrical overstress they should be shortened to the dama ged part If necessary the cable harness must be replaced completely Depending on th...

Page 10: ... Adels female connector Adels male connector C l i c k Attention Improper installation with risk of electrical shock Adels connector WAGO connector Never use the connectors without tention relief housing Please check that all connectors are plugged into the socket housing to the end stop There shall be no distance between the housing of the plug and the socket ...

Page 11: ...gure Ensure good contact Attention In order to operate this tanning device according to its intended use each of the following defects must be remedied corrected Route the wires min 1 2 inches vertically out of the connector plug Attention Never attach cable ties directly next to the connector plug 4 4 Check positions from inside Perfect condition min 1 2 in Incorrect conditions ...

Page 12: ...08 2017 Bad or no contact Missing cable ties Missing cable ties and messy cable routing 4 5 4 6 4 7 ...

Page 13: ... ballasts installed yes no 3 4 Approved capacitors installed Capacitors installed correctly and the connecting cables properly fixed in the clamps yes no Important positions 4 1 Check all connections externally for signs indicating elec trical overstress yes no 4 2 Check the connector and socket interior for signs of elec trical overstress yes no 4 3 Very important assembly information WAGO Adels ...

Reviews: