Interior unit lighting
LED - UNIT LIGHTING
If the tanning device is lighted by means of high-per-
formance-LED‘s, these can only be replaced by a
qualified specialist if they are defective. In this case,
contact the service department!
CONVENTIONAL UNIT LIGHTING
4
If the tanning device is lighted by means of fluores-
cent lights, proceed as follows:
TOP CROWN
• Undo the two screws at the facing of the “Tower
lighting in top crown” and remove the facing.
4
• Turn the lighting tube a quarter turn towards the
front and take it out towards the front.
• Replace the lighting tube and, if present, the colour
filter.
• Fasten the facing again.
DOOR
• Place a suction cup in the centre of the respective
pane and slowly pull the pane towards the front.
• Loosen the pane at one corner and go on down-
wards, then pull the pane off.
Caution!
Place the door panel carefully on a pad-
ded surface.
There is one decorative tube beneath the door panel.
Turn the tube a quarter turn to the right and take it
out towards the front. Replace the tube, the colour
filter (if present) and the starter. Fasten door panel
again.