23
Operation and Service megaSun 6900
Fig. 5-6-1: Undo the screw holding
the outer covering
Fig. 5-6-2: Undo the screws holding
the chrome covering
Fig. 5-6-4: Unscrew the re
fl
ector
Fig. 5-6-3: Disconnect the re
fl
ectors
at the respective ignition unit from
the electrical system
Fig. 5-6-5: Spread the clamp and
take off the burner including socket
Fig. 5-6-6: Insert the new burner and
ensure a snug
fi
t
Fig. 5-6-7: Insert the re
fl
ector
Fig. 5-6-8: Re
fl
ector correctly
positioned under the chrome cover
Flat projection