A s s e m b l y I n s t r u c t i o n s
|
KBL 4800
α
/ 5600
α
17
5.8 Connecting the external
timer
Pass both, the connector cable of the T-Max timer
and the leads of the tanning device, from the main
port through the cable entry in the rear wall to the
T-Max Box.
T-MAX CABLE ENTRY AT THE MAIN PLUG
(EXTERNAL CONNECTOR CABLE)
POSITION T-MAX BOX
Cable entry for
external connector
cable
T-MAX BOX
•
Remove the cover from the T-Max Box.
•
Insert the T-Max board to the socket pins of the
box.
•
Attach the connectors to the T-Max board and
housing (ground).
•
Attach the cover of the T-Max Box.
•
Fasten the timer above the T-Max box, using the
two screws.
TIMER
•
Connect the external cable and the timer to the
T-Max box.
• The exposure times stated in the expo-
sure schedule must be entered at the
External Timer.
• Information on how to enter the expo-
sure time can be found in the operating
instructions of your External Timer.
5.9 aquaCool and Aroma
connections
Danger due to leakages.
The device can be damaged by leaking
connections.
•
Slide the plastic tube
up to the stop
into the
quick connector socket.