7
Table 1: Specifications
Specifications
12V
6 Cell Unit
12V
10 Cell Unit
24V
10 Cell Unit
24V
12 Cell Unit
Electrical Characteristics
Operating Voltage Window
7 – 14.5V
7 – 14.5V
8 – 29V
8 – 29V
Maximum Voltage
18V
18V
30V
33V
Minimum Voltage
0V
0V
0V
0V
Internal Resistance
0.0011 ohms
0.0008 ohms
0.0019 ohms
0.0022 ohms
Capacitance
525 F
1250 F
315 F
263 F
Energy Stored within Operating
Voltage Window
42.3 kJ
101.6 kJ
122.4 kJ
102 kJ
Energy Stored at Max Voltage
85.1 kJ
141.8 kJ
141.8 kJ
142.9 kJ
Maximum Power
47 kW
112 kW
112 kW
94 kW
Leakage Current at Max Voltage
4.5 mA
4.5 mA
4.5 mA
4.5 mA
Operating Conditions
Operating Temperature Range
-40° – 185°F
(-40° – 85°C)
-40° – 185°F
(-40° – 85°C)
-40° – 185°F
(-40° – 85°C)
-40° – 185°F
(-40° – 85°C)
Cycle Life
>1,000,000
>1,000,000
>1,000,000
>1,000,000
Dimensions and Weight
Length x Width x Height
14.79” x 7.75” x 8”
19.44” x 7.75” x 8”
19.44” x 7.75” x 8”
19.44” x 7.75” x 8”
Weight
22 lb.
32.5 lb.
32.5 lb.
34.5 lb.
The KAPower KSM is a product of high electric power. Avoid shorting module
terminals. A brief short circuit will not cause product failure, however, it may result in
burning or igniting of combustible materials adjacent to the point of short circuit.
The KAPower module is polarity sensitive. Polarity shall be strictly observed when
connecting the KAPower module.
WARNING
CAUTION
Summary of Contents for KSM
Page 10: ...10 Figure 2 Typical Cable Installations ...
Page 11: ...11 Figure 3 Six 6 Cell KSM ...
Page 12: ...12 Figure 4 Ten 10 and Twelve 12 Cell KSM ...
Page 17: ...17 Figure 7 Standard MKSM Schematic ...
Page 23: ...23 Figure A1 Typical Cable Installations ...
Page 25: ...25 Figure A3 Schematic Alternate Source for Start Signal ...
Page 27: ...27 Figure B1 Typical Cable Installations ...
Page 29: ...29 Figure B3 Simplified Installation Diagram ...
Page 30: ...30 Figure B4 Standard DPST Install ...
Page 32: ...32 Figure C1 Typical Cable Installation ...
Page 33: ...33 Figure C2 Alternate Method ...