3.0 INTRODUCTION
The KSM enclosure houses a KAPower module, contactor, PLC Module (Programable Logic
Controller), circuit breaker, cables, conductors, and connectors. The cover of the KSM
enclosure can be removed by unscrewing and removing the ten (10) fasteners found on the
top and sides of the enclosure. The cover should only be removed for servicing or
troubleshooting at the direction of KBI.
KAPower is designed as an auxiliary power source to be installed in parallel with cranking
batteries. It derives its power from batteries or an engine charging system, and discharges
this power when needed. KAPower is intended for supplying electric power to various loads
operated in high pulse power (engine cranking) modes. KAPower will enhance and provide
for reliable cranking and starting of internal combustion engines. This capability may allow
for removal of half or most existing starting batteries.
The KAPower module can produce a significant electric charge. KAPower is not a
high voltage device. It supplies the same amount of voltage as its charge. A charged
module should be treated as a fully charged battery.
Do not short circuit KAPower module terminals. Burning or igniting of combustible
materials adjacent to the point of short circuit may result from a short circuit. Do not
place any conductive objects or materials across terminal posts. In case of accidental
short-circuiting of the KAPower module, or individual capacitors, immediately mitigate
short by removing the object causing short.
Noncompliance with the requirements set forth in this manual may result in
KAPower module failure. Such requirements shall be reviewed and followed in the
course of KAPower module operation and installation.
WARNING
WARNING
CAUTION
Summary of Contents for KSM
Page 10: ...10 Figure 2 Typical Cable Installations ...
Page 11: ...11 Figure 3 Six 6 Cell KSM ...
Page 12: ...12 Figure 4 Ten 10 and Twelve 12 Cell KSM ...
Page 17: ...17 Figure 7 Standard MKSM Schematic ...
Page 23: ...23 Figure A1 Typical Cable Installations ...
Page 25: ...25 Figure A3 Schematic Alternate Source for Start Signal ...
Page 27: ...27 Figure B1 Typical Cable Installations ...
Page 29: ...29 Figure B3 Simplified Installation Diagram ...
Page 30: ...30 Figure B4 Standard DPST Install ...
Page 32: ...32 Figure C1 Typical Cable Installation ...
Page 33: ...33 Figure C2 Alternate Method ...