3
Troubleshooting
3.1
Self-testing
When the device is powered on, all the fixed RJ45 LEDs on the front panel will flash
once, indicating that the ports are running normally and the Power (PWR1/2) and
Fault indicator lights will be illuminated if power is connected to the respective inputs
or not.
If problems are encountered when using this Ethernet switch please check the
following:
Verify that the correct power supply unit is being used; this unit requires a
48Vdc supply.
Ensure that the correct cables are being used to construct your network:
o
Unshielded Twisted Pair or Shielded Twisted Pair for RJ45 connections
o
100Ω Cat 3 cable or above for 10Mbps connections
o
100Ω Cat 5 cable or above for 100Mbps connections
o
100Ω Cat 5e cable or above for 1000Mbps connections
o
Twisted pair connection must not exceed 100m (328 feet)