6.2

 

 Class A ITE 

This  is  a  Class  A  product.  In  a  domestic  environment  this  product  may  cause  radio 
interference in which case the user may be required to take adequate measures. 
 

6.3

 

 FCC 

This equipment has been tested and found to comply with the limits for a Class A digital 
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the instruction 
manual, may cause harmful Interference to radio communications. Operation of this 
equipment in a residential area is likely to cause harmful interference in which case the 
user will be required to correct the interference at this own expense. 

 

6.4

 

UL 

 

Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the 
operating ambient temperature of the rack environment may be greater than room 
ambient. Therefore, consideration should be given to installing the equipment in an 
environment compatible with the maximum ambient temperature (Tma) specified by the 
manufacturer. 
 
Reduced Air Flow - Installation of the equipment in a rack should be such that the 
amount of air flow required for safe operation of the equipment is not compromised. 
 
Mechanical Loading - Mounting of the equipment in the rack should be such that a 
hazardous condition is not achieved due to uneven mechanical loading. 
 
Circuit Overloading - Consideration should be given to the connection of the equipment 
to the supply circuit and the effect that overloading of the circuits might have on 
overcurrent protection and supply wiring. Appropriate consideration of equipment 
nameplate ratings should be used when addressing this concern. 
 
Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. 
Particular attention should be given to supply connections other than direct connections 
to the branch circuit (e.g. use of power strips). 
 

 

Summary of Contents for EE1R3

Page 1: ...Extended Ethernet 100 Series Chassis User Manual EE1R3 ...

Page 2: ...3 3 1 2 TECHNICAL SPECIFICATION 3 2 INSTALLATION 4 2 1 PACKAGE CONTENTS 4 2 2 CONFIGURATIONS 4 2 2 1 Physical Connections 4 2 3 INSTALLATION METHOD 5 2 3 1 Chassis 5 2 4 POWER CONNECTIONS 5 2 5 LED STATUS 6 3 TROUBLESHOOTING 7 4 SYSTEM INSTALLATION EXAMPLE 7 5 DIMENSIONS 8 6 WARRANTY 9 6 1 WARRANTY INFORMATION 9 6 2 CLASS A ITE 10 6 3 FCC 10 6 4 UL 10 7 INSTRUCTION OF DISASSEMBLY 11 ...

Page 3: ...en media converters which are hot swappable The chassis is provided with an integral 100 240Vac 3 3A power supply and an AC power cord A fan provides air flow for system cooling and there are LED indicators for power and fan status 1 2 Technical Specification Connectors Converter Slots 15 Electromagnetic compatibility Interference FCC Part 15 Class A CE Power Power Input 100 240Vac 3 3A Power Cons...

Page 4: ...rter chassis with integral power supply unit Mounting brackets for 19 enclosure Rubber feet AC power cord Manual Note Extended Ethernet EE1CL units are sold separately Please contact you dealer or distributor if a part is missing or damaged within 10 days of receiving products 2 2 Configurations 2 2 1 Physical Connections Chassis front view P1 P2 FA FB Chassis rear view ...

Page 5: ...assis Locate the converter chassis with the 19 mounting rails and attach using the screws provided With the power switch in the OFF position connect the power cord and then select the ON position for the power switch Insert the EE1CL units into the EE1R3 chassis as required Connect required media cables to the EE1CL devices See section 3 5 for LED status 2 4 Power Connections This unit must be pow...

Page 6: ... of 12 www kbcnetworks com 2 5 LED Status LED Status Description Power PWR ON Power is supplied to the chassis OFF No power to the chassis FAN FAN A ON The fan is functioning correctly OFF The fan is not powered or there is a fault with the fan Note PWR2 and FAN B LEDs are not used on this product ...

Page 7: ...o indicate the presence of power If the green light does not come on check that the power switch is in the ON position With power to the chassis the green fan light should be lit to show that the fan is functioning correctly If the fan LED remains off when the power is on there is a fault with the Fan please contact KBC Networks 4 System Installation Example Figure 4 1 EE1R3 Typical System Install...

Page 8: ... Ethernet User Manual Manual EE1R3_Series Rev1208A Copyright KBC Networks Ltd 2012 Page 8 of 12 www kbcnetworks com 5 Dimensions 440mm 88 5mm Chassis front view Chassis depth 140mm Chassis rear view P1 P2 FA FB ...

Page 9: ...moisture and circuit modification b SHOULD THIS PRODUCT PROVE DEFECTIVE FOLLOWING PURCHASE THE BUYER NOT THE MANUFACTURER DISTRIBUTOR OR RETAILER ASSUMES THE ENTIRE COST OF ALL SERVICING OR REPAIR EXCEPT AS OTHERWISE PROVIDED BY THE TERMS OF THIS WARRANTY c FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY ON THIS PRODUCT THE BUYER IS LIMITED TO THE FOLLOWING DAMAGES 1 THE COST OF LABOR TO REPAIR OR R...

Page 10: ...ated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer Reduced Air Flow Installation of the equipment in a rack should b...

Page 11: ...ruction of Disassembly of KBC Product For EU Directive 2002 95 EEC WEEE Tools required No 1 Phillips screwdriver No 2 Phillips screwdriver Steps for disassembly 1 Remove screws to cover plate 2 Remove cover plate 3 Remove mounting screws for printed circuit board PCB 4 Take out all PCBs Notice When a product reaches the end of its life return to KBC Networks ...

Page 12: ...630 U S A Americas Phone 1 949 297 4930 Fax 1 949 297 4933 KBC Networks Ltd EMEA KBC Networks Ltd Barham Court Teston Maidstone Kent ME18 5BZ United Kingdom Phone 44 0 1622 618787 Fax 44 0 20 7100 8147 Email info kbcnetworks com Web www kbcnetworks com data delivered ...

Reviews: