Indoor
Wall
Outdoor
Correct orientation of Mounting Plate
Page 21
Step 3: Drill wall hole for connective piping
1. Determine the location of the wall hole based on the
position of the mounting plate. Refer to Mounting
Plate Dimensions.
2. Using a 65mm or 90mm (depending on models) core
drill, drill a hole in the wall. Make sure that the hole is
drilled at a slight downward angle, so that the outdoor
end of the hole is lower than the indoor end by about
5mm to 7mm. This will ensure proper water drainage.
NOTE: When the gas side connective pipe is
Ø
16mmor more,
the wall hole should be 90mm.
3. Place the protective wall cuff in the hole. This protects
the edges of the hole and will help seal it when you finish
the installation process.
CAUTION
When drilling the wall hole, make sure to avoid wires,
plumbing, and other sensitive components.
MOUNTING PLATE DIMENSIONS
Different models have different mounting plates. For
the convenience of installation, there are bubble level,
carved dimensions on the mounting plate. Please install
the plate and drill wall hole according to the information
of the mounting plate. See the figures below.
Unit: mm(inch)
CAUTION: The Bubble level on the mouting plate can't be
removed. If it is broken, make sure to clean up the leaking
liquid.
Horizontal direction ruler
Vertical direction
ruler
Indoor unit outline
Indoor unit outline
Indoor unit outline
Model B
Model C
pipe hole
pipe hole
pipe hole
pipe hole
pipe hole
pipe hole
Model A