22
To prevent distortion when the compressor starts
(you can find the unit’s power information on
the rating sticker):
• The unit must be connected to the main
outlet. Normally, the power supply must
have a impedance of 32 ohms.
• No other equipment should be connected
to the same power circuit.
NOTE:
The fuse is made of ceramic.
Outdoor Unit Wiring
1. Prepare the cable for connection
a. You must first choose the right cable size.
Be sure to use H07RN-F cables.
Wiring
The air conditioner’s printed circuit board(PCB) is
designed with a fuse that provides overcurrent
protection. The specifications of the fuse are
printed on the circuit board, such as:
Indoor unit:
T5A/250VAC, T10A/250VAC.
(applicable for unit adopts R32 refrigerant)
Outdoor unit:
T20A/250VAC (for <24000Btu/h
unit), T30A/250VAC (for >24000Btu/h unit)
TAKE NOTE OF FUSE SPECIFICATIONS
WARNING
WARNING
Wiring must be done by a qualified
technician. Improper connections may
cause electrical malfunction, injury, or fire.
DO NOT
modify the length of the power
cord or use an extension cord.
CAUTION
Safety Precautions
• Connect the outdoor wires before
connecting the indoor wires.
• Make sure you ground the unit. The
grounding wire should be located away
from gas pipes, water pipes, lightning rods,
telephone wires or other grounding wires.
Improper grounding may cause electrical
shock.
•
DO NOT
connect the unit to the power
source until all wiring and piping is
completed.
• Make sure that you do not cross your
electrical wiring with your signal wiring.
This may cause distortion and interference.