Power Specifications
NOTE:
Electric auxiliary heating type circuit breaker/fuse need to add more than 10 A.
Indoor Power Supply Specifications
MODEL
(Btu/h)
≤
18K
19K~24K 25K~36K 37K~48K 49K~60K
POWER
PHASE
1 Phase
1 Phase
1 Phase
1 Phase
1 Phase
VOLT
VOLT
VOLT
VOLT
208-240V 208-240V 208-240V 208-240V 208-240V
CIRCUIT BREAKER/
FUSE(A)
25/20
32/25
50/40
70/55
70/60
MODEL
(Btu/h)
≤
36K
37K~60K
≤
36K
37K~60K
POWER
PHASE
3 Phase
3 Phase
3 Phase
3 Phase
380-420V
380-420V
208-240V
208-240V
CIRCUIT BREAKER/FUSE(A)
25/20
32/25
32/25
45/35
MODEL
(Btu/h)
≤
18K
19K~24K 25K~36K 37K~48K 49K~60K
POWER
PHASE
1 Phase
1 Phase
1 Phase
1 Phase
1 Phase
208-240V 208-240V 208-240V 208-240V 208-240V
CIRCUIT BREAKER/
FUSE(A)
25/20
32/25
50/40
70/55
70/60
MODEL
(Btu/h)
≤
36K
37K~60K
≤
36K
37K~60K
POWER
PHASE
3 Phase
3 Phase
3 Phase
3 Phase
380-420V
380-420V
208-240V
208-240V
CIRCUIT BREAKER/FUSE(A)
25/20
32/25
32/25
45/35
Outdoor Power Supply Specifications
CAUTION
•
While connecting the wires, please strictly follow the wiring diagram.
•
The refrigerant circuit can become very hot. Keep the interconnection cable away from the
copper tube.
5. Clamp down the cable with the cable clamp.The cable must not be loose or pull on the u-lugs.
6. Reattach the electric box cover.