6.11.3
Birger Setup
Iron CoaXPress cameras have integrated Gen<i>Cam parameters for controlling Birger lens adapters.
Figure 26 – Iron CoaXPress with Birger
1.
Mount the Birger adapter with a lens, and connect it to the GPIO while the camera is turned off.
2.
Set “LensSelector” as “Birger” to select Birger adaptor control.
3.
Initialize the Birger using “LensInit” command. The Birger will calibrate and move to initial position. Please
note that this process might take a few minutes to learn the specific steps of the lens.
4.
After a successful initialization, the lens info, “LensFocusControl”, “LensIrisControl” and
“LensCommandControl” categories will be available to control the different lens components.
5.
Recommended: Use the “UserSetSave [UserSetSelector]” command to save this preset and remove the
need to initiate the Birger in future sessions.
Figure 27
Birger mount Control
parameter configuration in GenICam Browser
Sky Blue Microsystems GmbH