Kaya Instruments Chameleon II Hardware Reference And Installation Manual Download Page 24

 

 

 

 

 

 

 

  

 

Page no. 23 | Installation & Configuration

 

 

 
 

12.3

 

CLHS Cards 

 

12.3.1

 

Installing & Removing SFP+ Modules 

 

The purpose of this section is to demonstrate how to install SFP+ transceiver module, attach an optical network 
cable and remove an  SFP+ transceiver  module. It is necessary to  understand the correct way of installing and 
removing an SFP+ transceiver, as correct operation can protect the module from being damaged and ensure its 
stable performance. Before removing or installing an SFP+ module, please follow the precautions and installation 
instructions. 
 

12.3.2

 

Precautions 

 

1.

 

Use an ESD-preventive wrist or ankle strap and follow its instructions for use. 

2.

 

Make sure there is no dust or any other foreign matter inside the SFP+ module, or blocking any of the 
connectors. 

3.

 

Clean the optic surfaces of the fiber cables before plugging them into the optical ports of an SFP+ module. 

4.

 

Removing  and  inserting  a module  can  shorten  its  useful  life, so  you should  not  remove  and  insert  the 
module any more often than is absolutely necessary. 

5.

 

Insert the clean dust covers into the module after the cables are removed. Do not remove the dust plug 
until you are ready to attach the network interface cable. 

6.

 

Do not install or remove the SFP+ module with fiber-optic cables attached to it because of the potential 
of damaging the cable, the cable connector, or the optical interfaces in the module. 

7.

 

Disconnect all cables before removing or installing a module. 

8.

 

Place the removed module on an antistatic mat or a static shielding bag if you plan to return it to the 
factory. 

9.

 

Protect the line card by inserting clean module cage covers into the optical module cage when there is no 
module installed. 

10.

 

Keep  the  protective  dust  plugs  installed  in  the  unplugged  fiber-optic  cable  connectors  and  in  the 
transceiver optical bores until you are ready to make a connection. 

 

12.3.3

 

Installing the SFP+ Module 

 

In order to install the SFP+ module, follow these steps: 
 

1.

 

The Komodo II CLHS Frame Grabber supports the following SFP+ modules: 

-

 

KY-SFP-10G31-10 – Allows of up to 10km connection over single mode fiber cable. 

-

 

KY-SFP-10G85-3M – Allows of up to 300m connection over multi-mode fiber cable. 

2.

 

Remove the dust plugs from the module as shown in figure 14 (a). 

3.

 

The SFP+ module has a bale clasp that used to remove or install the SFP+ module.  

4.

 

Close the bale clasp before inserting the SFP+ module. 

5.

 

Line up the module with the port and slide it into the port as shown in figure 14 (b). 

6.

 

Make sure that the male connectors on the module will align with the female connectors inside the cage. 

7.

 

Verify that the modules are completely seated and secured in their assigned receptacles on the line card 
by  firmly  pushing  on  each  module.  In  case  the  module  is  not  completely  seated  and  secured  in  the 
receptacle, you will hear a click as the triangular pin on the bottom of the module snaps into the hole in 
the receptacle. 

Summary of Contents for Chameleon II

Page 1: ...Blue Microsystems GmbH Geisenhausenerstr 18 81379 Munich Germany 49 89 780 2970 info skyblue de www skyblue de In Great Britain Zerif Technologies Ltd Winnington House 2 Woodberry Grove Finchley Lond...

Page 2: ...3 3 TTL Inputs Outputs 14 9 3 4 LTTL Inputs Outputs 14 9 3 5 Isolated Input 15 9 3 6 Isolated Output 16 10 Mechanical Specifications 17 10 1 Mechanical Drawings 17 10 1 1 Predator II CoaXPress Mechan...

Page 3: ...ra topology 25 1 2 List of tables Table 1 Revision History 3 Table 2 PCIe working modes 9 Table 3 Connector indicator lamp states 10 Table 4 Connector indication lamp timings 10 Table 5 Status indicat...

Page 4: ...Initial release Sky Blue Microsystems GmbH Geisenhausenerstr 18 81379 Munich Germany 49 89 780 2970 info skyblue de www skyblue de In Great Britain Zerif Technologies Ltd Winnington House 2 Woodberry...

Page 5: ...if dropped or damaged Otherwise a fire or electric shock may occur Do not touch the product with metallic objects Otherwise a fire or electric shock may occur Do not place the product in dusty or humi...

Page 6: ...unusable state business interruption or others Use of this product in any manner that contradicts this manual or malfunctions that may occur due to connection to other devices Damage to this product...

Page 7: ...o II CLHS and Chameleon II The guide consists of 8 chapters split into two main parts the first chapters 5 through 11 refers to the hardware of the cards and includes an overview and interface layouts...

Page 8: ...Card Overview 5 Card Overview 5 1 Predator II CoaXPress Connectors and LEDs Layout Figure 1 Predator II connector topology 5 2 Chameleon II Connectors and LEDs Layout Figure 2 Chameleon II connector...

Page 9: ...o 8 Card Overview 5 3 Komodo II CoaXPress Connectors and LEDs Layout Figure 3 Komodo II CoaXPress connector topology 5 4 Komodo II CLHS Connectors and LEDs Layout Figure 4 Komodo II CLHS connector top...

Page 10: ...ted in the following table Card Newest Supported PCIe Generation Maximal Bandwidth Newest PCIe Generation Predator II CoaXPress Gen 2 4 up to 4 lanes 12 Gbps Chameleon II CoaXPress Gen 3 up to 8 lanes...

Page 11: ...gress PoCXP not in use Slow pulse red No camera is connected Solid red PoCXP over current Table 3 Connector indicator lamp states Indication Timing Fast flash 12 5Hz 20ms on 60ms off Slow flash 0 5Hz...

Page 12: ...channel uplink channel and power transmission simultaneously BELDEN Name Belden 7731A Belden 1694A Belden 1505A Belden 1505F Belden 1855A Type Long Distance Industry Standard Compromise Coax Flexible...

Page 13: ...itive signal of LVDS pair 7 LVDS Output 1p LVDS output LVDS Negative signal of LVDS pair 8 LVDS Output 1n LVDS output LVDS Negative signal of LVDS pair 9 Optocoupled Output 0 Opto Isolated output Up t...

Page 14: ...nits Pulse width 50 ns Pulse rate 0 5 MHz 10 90 rise fall time 0 3 1 4 ns Table 10 LVDS inputs DC AC characteristics 9 3 2 LVDS Outputs OUT OUT Data Out DS90LV049 Figure 7 LVDS inputs schematics DC Ch...

Page 15: ...able 13 TTL inputs outputs DC characteristics AC Characteristics Parameter Conditions Min Typical Max Units Pulse width 50 ns Pulse rate 0 5 MHz Table 14 TTL inputs outputs AC characteristics 9 3 4 LT...

Page 16: ...Figure 10 Isolated input schematics When input current exceeds the threshold the input logic state is HIGH DC Characteristics Parameter Conditions Min Typical Max Units Input Voltage 6 50 V Input curr...

Page 17: ...conductive state switch ON DC Characteristics Parameter Conditions Min Typical Max Units Input Voltage 6 50 V Input current threshold 3 mA DC Isolation 250 V AC Isolation 150 VRMS Table 19 Isolated ou...

Page 18: ...no 17 Mechanical Specifications 10 Mechanical Specifications 10 1 Mechanical Drawings 10 1 1 Predator II CoaXPress Mechanical Drawing 10 1 2 Chameleon II CoaXPress Komodo II CoaXPress Mechanical Draw...

Page 19: ...Page no 18 Mechanical Specifications 10 1 3 Komodo II CLHS Mechanical Drawing...

Page 20: ...or II CoaXPress 130 gr Chameleon II CoaXPress 225 gr Komodo II CoaXPress 225 gr Komodo II CLHS 225 gr Table 21 Card s weight Storage and operating temperature are identical for all four cards Specific...

Page 21: ...cation Values 3 3V power supply 0 3V to 3 7V 12V power supply 0 3V to 14V Table 23 Absolute maximum electrical ratings Card Minimum voltage V Maximum voltage V LVDS 0 3 3 6 Opto isolated in 6 0 60 Opt...

Page 22: ...Multimedia Device At this stage you should Cancel the installation The compatible drivers for your card will be installed during the installation of our Vision Point software Windows and Linux only M...

Page 23: ...pin will move in the channel locking the connector in position Figure 13 Twisting the connector and securing it in position To remove the cable repeat the process from finish to start twist the conne...

Page 24: ...e optical interfaces in the module 7 Disconnect all cables before removing or installing a module 8 Place the removed module on an antistatic mat or a static shielding bag if you plan to return it to...