8.  Practical tips

 
Prior to using the pump for the first time and after every usage, clean your 

mamivac

®

 suction kits

 as

described in the respective operating instructions. Please check whether all parts are undamaged. Make
sure to assemble the parts properly again as shown in the instructions. Prior to expressing, always wash
your hands thoroughly with soap and wipe the breast with a damp cloth. To avoid dry, sore or cracked
nipples, do not use soap or alcohol as detergent. Prepare yourself for the expressing with ease. Take a  
comfortable and relaxed seat.

• 

Gently press the breast shield over the nipple for a tight contact.

• 

You can operate the 

mamivac

®

 SENSITIVE-C

 breast pump either with one or two suction kits. To save 

time, it is possible to express both breasts simultaneously (double pumping).

• 

Start to express milk. Please observe the instructions for operating explained in Chapter 3.

• 

The pump features a stimulation mode to support milk production. You can also use your free hand for 
an additional breast massage to support the flow of milk.

• 

Express both breasts alternately, unless instructed otherwise by your physician.

• 

When expressing make sure not to overfill the milk bottle. With a capacity of 125 ml, we recommend 
to interrupt expressing when the 100 ml mark is reached and fill the expressed breast milk to another 
container/bottle. Turn the bottle counterclockwise to unscrew it from the breast shield.

• 

For further information regarding breast shield size please ask your lactation consultant or midwife.

• 

Since expressing times strongly depend on the individual mother, you are asked to contact your midwi-
fe or breastfeeding assistant. As a rule of thumb, the following expressing times are recommended:

With one suction kit:

Expressing scheme: Express first and second breast 5 minutes each one after the other, followed by  
3 minutes and 2 minutes each.

With two suction kits:

Express both breasts simultaneously for 10 minutes (double pumping). Have a look at the fill level of 
the bottle at the suction kit from time to time and make sure it does not overflow.

8.1 Storing breast milk

Breast milk can be stored as follows:

• 

Freshly expressed milk at room temperature (16 °-29 °C) 3-4 hours

• 

In the rear of the fridge (below 4 °C) 3 days

• 

In the freezer (-18 °C) 6 months

Fill the used bottles or containers to two thirds only and write down the fill date. Instead of a bottle, you can 
also use our specially designed

 mamivac

®

 breast milk freezer bags

 [REF 282100]. Do not defrost frozen 

breast milk in the microwave, but at room temperature. Place the bottle or bag in warm water as required. 
After defrosting, gently shake the container or bag to mix the milk.

9.  Troubleshooting

The hygienic diaphragm of the suction kit effectively prevents that liquids or solids are sucked into the pump.
If substances are sucked in nevertheless or any other problem occurs, immediately put the device out of
operation. Contact your rental station or directly the manufacturer’s customer service.

Summary of Contents for MAMIVAC SENSITIVE-C

Page 1: ...rating instructions electric breast pump for rental Phone 49 0 71 56 1 76 02 100 Fax 49 0 71 56 1 76 02 500 info kaweco de KaWeCo GmbH Gerlinger Str 36 38 71254 Ditzingen Germany REF 284000 As of 2018...

Page 2: ...7 3 3 The stimulation phase 17 3 4 The expressing phase 17 3 5 Switching off the device 18 4 Hygiene and cleaning 18 4 1 Cleaning and servicing the breast pump 18 4 2 Cleaning and servicing the mamiva...

Page 3: ...aration of infant from mother metabolic disorders of the baby anatomic disorder in the face of the infant cleft lip jaw palate diseases of the mother where breastfeeding is temporarily contraindicated...

Page 4: ...ly adjustable cycle control c Status LED flashing green ready for use yellow self testing red error message d Connection for power unit e Connection for suction kit f Connection for second suction kit...

Page 5: ...cycles stimulate the flow of milk Turn on the pump by switching the vacuum control to Make sure that the vacuum control indicator is in the area marked green low vacuum Turn the cycle control to a hig...

Page 6: ...ng vacuum in the breast shield to prevent damage to the tissue After cleaning rinse all parts thoroughly with lukewarm water to remove residues of the washing up liquid especially on those components...

Page 7: ...pected WARNING Avoid using this device directly next to other devices or with other devices stapled on top of each other as this could disturb operation WARNING The use of accessories converters or ca...

Page 8: ...screw it from the breast shield For further information regarding breast shield size please ask your lactation consultant or midwife Since expressing times strongly depend on the individual mother you...

Page 9: ...be returned to the manufacturer 10 Environmental protection and disposal Please dispose of mamivac SENSITIVE C breast pumps in accordance with your local disposal regulations for electrical devices 11...

Page 10: ...ructions 14 Accessories and spare parts Designation REF mamivac SENSITIVE C breast pump device 281012 mamivac suction kit PREMIUM L 283120 mamivac double kit PREMIUM L 283123 mamivac suction kit PREMI...

Reviews: