4.Installation direction
Acceptable Acceptable Acceptable Not acceptable Not acceptable
※U2G-370B series is horizontal only.
5.When installing, make sure to fix it using the mounting holes in the blower securely.
Dimensions for installation is as follows.
5
Piping
5.1 Piping
1.Install piping supports so that the piping’s load is not applied directly onto the blower.
2.Secure a flexible hose or pipe length of 1 m or more.
Do not put fingers in the discharge or suction port while driving. There is a risk of injuries.
3.Attach a special accessory or a commercially available air filter to the discharge and suction port.
Do not inhale the release powder of the sound absorbing material. There is a risk of suffocations or
damaged.
(Note) If the piping is long or thin, or has many bents or obstacles, the static pressure and air volume will drop.