16
―
Please check the following inspection items from time to time, and perform maintenance and replace
consumable parts as necessary. Wear appropriate protective equipment such as helmets and gloves
when working.
8.1 Daily inspection
Check item
Failure criterion
Noise value/vibration
No change from the time of installation.
In order to discover abnormalities early, it is important to get to know a daily change.
We recommend to keep journal operation diary for that purpose.
8.2 Periodic inspections
Check item
Contents
Motor surface
Dust or oil, etc., adhering to the surface are cleaned.
Blower section
Check whether the air performance has dropped.
Be careful when using solvent or similar to clean the blower. Inappropriate use of solvent may result
in poisoning. Futhermore, thinner and/or benzene may change or discoloration of blower painting.
8.3 Consumable parts
The following parts are consumable parts.
Please request the replacement of parts by referring to the guideline for replacement.
Parts name
Replacement frequency
Estimated condition
Bearing
2 years
When generation of heat noise, and unusual
vibration occur.
Sound absorbing
material
2 years
When the noise increases, or when the sound
absorbing material has hardened or deformed.
・If abnormal in daily maintenance and check, we will recommend you repair a little early.
・If the sound absorbing material degrades, particles that peel off could be discharged to the
secondary side of the blower.
9
Trouble shooting
● If the blower does not run, or if there are any abnormalities, stop operation immediately and
turn the power OFF, lock it. Contact your dealer or designated service center for inspection
and repairs.
●Always turn the power OFF, lock it, and ensure that no power is being supplied to the blower
before starting maintenance service. Failure to observe this could result in electric shocks
or injuries.
●The product must never be disassembled, repaired or modified by any person other than a qualified
repair technician. Improper repairs could lead to electric shocks, fires or air leaks.
When there are any abnormalities after carrying out the check item of the following table,
!
WARNING
Summary of Contents for Showa Denki U2G-70T
Page 19: ... 19 ...
Page 20: ... 20 ...