Page 1: ...Instructions for use KAVOLUX 1410 C Always be on the safe side...

Page 2: ...Distributed by KaVo Dental GmbH Bismarckring 39 D 88400 Biberach Phone 49 7351 56 0 Fax 49 7351 56 1488 Manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach www kavo com...

Page 3: ...nge 11 3 3 Rating plates 12 3 4 Technical data and requirements 13 4 Assembly 14 4 1 Packaging 14 4 1 1 Transportation and storage 14 4 1 2 Packed items 14 4 1 3 Removal from the packaging 14 4 2 Moun...

Page 4: ...pecifications on the electromagnetic compatibility in accordance with EN 60601 1 2 41 11 1 Guidelines and manufacturer s statement Electromagnetic uses 41 11 2 Guidelines and manufacturer s statement...

Page 5: ...tructions 1 1 2 Symbols See the Safety Warning Symbols section Important information for users and technicians CE mark European Community A product bearing this mark meets the requirements of the appl...

Page 6: ...er supplies or chemical or electrical factors deemed abnormal or impermissible in accordance with factory specifications The warranty does not usually cover bulbs glassware rubber parts and the col ou...

Page 7: ...ply with any of the above obligations will mean that the damage will be considered to have arisen following delivery in accordance with ADSp Art 28 Outside Germany Note KaVo is not liable for damage a...

Page 8: ...tation Note Please keep the packaging in case you need to return the product for servicing or repair The symbols printed on the outside are for transportation and storage and have the following meanin...

Page 9: ...mage to property or mild to moderate injuries WARNING WARNING indicates a hazardous situation that can cause death or serious injury DANGER DANGER indicates a hazardous situation that can directly cau...

Page 10: ...requirements and regulations of VDE 0107 and VDE 0100 The safety checks SC must be done at 24 month intervals See also 8 Safety checks Page 34 2 2 1 Information on electromagnetic compatibility Note...

Page 11: ...ge www enretec de of enretec GmbH you can download a form for a disposal request under the menu item eom or you can use it as an online request 2 Fill out the request with the corresponding informatio...

Page 12: ...ion on the KaVo treatment centres ESTETICA E80 E70 and E50 3 1 Treatment light 1 2 3 4 5 6 7 Components of the KAVOLUX 1410 C Mounting pole Handles Swivel arm Protective shield Spring arm Lamp head Re...

Page 13: ...of equipment Collisions could be caused by the required degrees of freedom and the large swivel range Always move or swivel the operating light with great care Dimensions in mm Instructions for use KA...

Page 14: ...Rating plates The rating plate of the operating light is located on the top side of the swivel arm RE F Rating plate of the KAVOLUX 1410 C L Instructions for use KAVOLUX 1410 C 3 Product description 3...

Page 15: ...nsumption max 150 VA Illumination intensity approx 8 000 to 30 000 Lux Colour temperature approx 4 300 to 5 000 Kelvin Environmental conditions Operating environment temperature 10 C to 40 C Relative...

Page 16: ...1060 hPa 4 1 2 Packed items Packaged item Operating light with accessories and mounting pole Length 1 100 mm Width 600 mm Height 470 mm Gross weight Approx 23 kg Net weight Approx 16 kg 4 1 3 Removal...

Page 17: ...he unit Note Comply with the provisions of IEC 601 Turn off the main switch before mounting The assembly of the device comprises the following steps in the specified se quence Install the mounting pol...

Page 18: ...4 2 2 ESTETICA E50 Install the mounting pole Instructions for use KAVOLUX 1410 C 4 Assembly 4 2 Mounting the device 16 44...

Page 19: ...e cover of the connection point Screw off the cover Loosen screw below the main switch Loosen the fastening screws of the cladding see arrow and remove the clad ding Instructions for use KAVOLUX 1410...

Page 20: ...completely Slide the cover Mat no 0 764 7643 onto the mounting pole Insert the mounting pole into the lamp holder Positioning the mounting pole It is approx 1800 mm from the top edge to the floor The...

Page 21: ...wivel arm Use four screws M6 x 12 Mat no 0 249 4195 to mount the holder Mat no 1 003 7000 to the lamp mounting pole Place the cover Mat no 1 003 6999 on the mounting pole and affix with the screw Mat...

Page 22: ...e hole in the mounting pole and then downward until they exit the bottom end of the mounting pole Place the cap Mat no 1 003 7006 on the swinging arm Instructions for use KAVOLUX 1410 C 4 Assembly 4 2...

Page 23: ...6 V45 V82 V81 V83 F1 F2 F3 F4 F5 F6 F7 X7 CAN R on on V87 B1 X11 Mat no 1 007 4808 Slot X31 Voltage supply brown X13 24 V Voltage supply blue X13 0 V Plug on the connector X31 of the control line at s...

Page 24: ...4 2 3 ESTETICA E70 ESTETICA E80 Install the mounting pole Instructions for use KAVOLUX 1410 C 4 Assembly 4 2 Mounting the device 22 44...

Page 25: ...ock position corresponds to the direction of the main switch of the unit Fix the mounting pole with clamping screws and PE screw Guide the cover ring on the unit body as far as it will go Note When th...

Page 26: ...t Carry out the appropriate safety check for the treatment unit Mount the device covers 4 3 Set the lamp voltage After installation the lamp voltage must be set in service mode Note Only a service tec...

Page 27: ...S2 Reduce value S3 Increase value S6 Save value Set the voltage at the lamp to 12 5VAC with a normal voltmeter or Set the voltage at the lamp to 16 5VAC with an RMS normal voltmeter After setting the...

Page 28: ...mp voltage of the halogen lamp change the correction value with the service tester I2 C if necessary and set it to the voltage values descri bed above To quit the service mode press and hold the Decre...

Page 29: ...n keys Description S1 Store settings S2 Increase light voltage correction value S3 Reduce light voltage correction value Press and keys S2 and S3 to set the correction value between 0 and 25 The defau...

Page 30: ...Adjusting the light head brake Note The light head brake determines the ease of the vertical swinging of the glass re flector CAUTION Lamp may be hot Injury hazard Remove the protective shield only w...

Page 31: ...the protective shield upward with one hand and remove Remove the nuts and tighten the setscrew by turning it to the right so that the light head is freely movable and remains in each position 1 Lock...

Page 32: ...6 Operation Note The operation of the KAVOLUX 1410 C operating light is described in the In structions for Use of the treatment unit Instructions for use KAVOLUX 1410 C 6 Operation 30 44...

Page 33: ...product or product parts in water or other fluids Note Do not use solvents or aggressive chemicals Note Use disinfectant in accordance with manufacturer s instructions 7 2 Cleaning and disinfecting th...

Page 34: ...ectants FD 322 D rr Mikrozid AF made by Sch lke Mayr liquid or cloths Reattach the protective shield 7 3 Cleaning and disinfecting the handles Remove the handles by pressing the spring loaded catches...

Page 35: ...ectants in accordance with the Instructions for Use of the manufac turer See also Disinfectant material safety data sheet Snap the handles on again 7 4 Sterilisation 7 4 1 Sterilising the handles Note...

Page 36: ...m the joints the gas spring and handles for me chanical strength and damage Check the protective conductor connections The safety check of the KAVOLUX 1410 C operating light is carried out as part of...

Page 37: ...e Do not touch the dental reflector with your fingers Turn the protective shield upward with one hand and remove Remove the setscrews from the defective side of the dental reflector or on both sides 1...

Page 38: ...the protective cover 9 2 Exchange the halogen lamp Halogen lamp Mat no 0 740 4211 Note To increase the service life of the halogen lamp turn off the light during breaks between treatments CAUTION Lam...

Page 39: ...ss bulb of the new halogen lamp with your fingers Screw the wires of the new halogen lamp tightly to the luster terminal Check if the wires are tightly seated Remove protective sheath Instructions for...

Page 40: ...Insert the new halogen lamp into the guide Let the retention spring lock in place Mount the protective cover Instructions for use KAVOLUX 1410 C 9 Repair 9 2 Exchange the halogen lamp 38 44...

Page 41: ...9 3 Exchange the gas spring Note Only trained technicians may change the spring Instructions for use KAVOLUX 1410 C 9 Repair 9 3 Exchange the gas spring 39 44...

Page 42: ...treatment unit is off Turn the main switch of the treatment unit on The treatment light turns off and on sporadically The thermal fuse for pro tecting the operating light is tripped The thermal fuse...

Page 43: ...for residential purposes Transmission of voltage fluctua tion Flicker according to IEC 61000 3 3 Class A The is suitable for use in all equip ment including devices in living areas and suitable for e...

Page 44: ...ri od 40 V 60 drop in V T for 5 periods 70 V 30 drop in V T for 25 periods 5 V 95 drop in V T for 5 s 250 periods 5 V 95 interrup tion of the V T for peri od 40 V 60 drop in V T for 5 periods 70 V 30...

Page 45: ...magnetic waves is absorbed and reflected by buildings objects and people a The ISM frequency bands for industrial scientific and medical applications be tween 150 kHz and 80 MHz are 6 765 MHz to 6 79...

Page 46: ...er of the transmitter in Watts 150 kHz through 80 MHz d 1 17 P 80 MHz through 800 MHz d 1 17 P 800 MHz through 2 5 GHz d 2 33 P 0 01 0 1 0 1 0 2 0 1 0 4 0 4 0 7 1 1 2 1 2 2 3 10 3 7 3 7 7 4 100 11 7 1...