Short instructions for use 1 Controls

5

1.2 Dentist element S-table

Tab "Treatment"

Direct keys "Chair functions"

"Most recent position" und "Rinse posi-
tion" keys

Display "Time of day"

Display "User"

Selection of type of treatment

"Automatic positions" keys

"Collapsed position" key

"Tumbler filler" key

"Operating light dimming" key

"Operating light" key

Summary of Contents for ESTETICA E70 Vision

Page 1: ...Short instructions for use ESTETICA E70 Vision E80 Vision...

Page 2: ...Distributed by KaVo Dental GmbH Bismarckring 39 88400 Biberach Germany Phone 49 7351 56 0 Fax 49 7351 56 1488 Manufacturer KaVo Dental GmbH Bismarckring 39 88400 Biberach Germany www kavo com...

Page 3: ...u 20 4 6 Settings menu 23 4 7 Operation of the operating light KaVoLUX 540 LED optional 23 5 Operate instruments with the foot control 27 5 1 Menu CONEXIO operate with foot control 28 6 Hygiene 29 6 1...

Page 4: ...use and safe operation of the product The user must ensure that the unit works properly and is in satisfactory condition before each use 1 1 Dentist element T table and cart Touchscreen E70 Vision E80...

Page 5: ...Tab Treatment Direct keys Chair functions Most recent position und Rinse posi tion keys Display Time of day Display User Selection of type of treatment Automatic positions keys Collapsed position key...

Page 6: ...rols 6 1 3 Assistant element 10 Direct keys Chair functions Last position key Rinse position key Automatic positions keys Timer keys Bowl rinsing key Tumbler filler key Operating light dimming key Ope...

Page 7: ...vel Mode key Key Name SCHEM Anwend Benutze Client St IndexSe Konfigur Letztes U Lizenzen Server A Server A Server A Server W SP key rinsing position LP key last position AP 1 key automatic position 1...

Page 8: ...element Operating light dimming key Dentist element and assistant element Laser mode key dentist element only Direct keys selectable in Settings tab Key Name Control element Tumbler filler key Dentist...

Page 9: ...control and wireless foot control Stirrup switch LP preselected spray foot switch Chair position direction of motor rota tion cross switch SP blown air foot switch Level preselection handpieces foot p...

Page 10: ...to switch between the function levels Func tion level Key Dentist element Key Assistant s ele ment Active quadrant Function 1 Quadrant 4 Setting the chair height and back rest position 2 Quadrant 1 Se...

Page 11: ...ifted and lowered Requirement Function level 2 is active Quadrant 1 lights up If the desired function level is not activated press the Mode key possibly re peatedly if needed Please refer to Setting t...

Page 12: ...Move to the collapsed position Briefly press the desired button Chair automatically moves to the saved position The key is activated as soon as the saved position is reached Move the chair to the des...

Page 13: ...the key for the desired direction Bar length long The headrest for wards Bar length short Special function 1 for small persons with round shoulders compensation is switched off Press the joystick All...

Page 14: ...be emptied into the mouth rising basin when the devices is turned off Mechanical and electronic damage could occur as a result of overflowing liquid The patient part can be swivelled using a motor ad...

Page 15: ...bs Treatment menu Timer menu CONEXIO menu Cleaning menu Settings menu Tap a tab to display the corresponding menu Tab Menu Description Treatment Selection of type of treatment Speed power Direction of...

Page 16: ...der Use the slider to increase or decrease a value Increase value key Press the Increase value key to increase a value Decrease value button Press the Decrease value key to decrease a value Save icon...

Page 17: ...fic values can be displayed and set in the Treatment menu Handpiece specific settings Extracted instrument Display Setting options Pneumatic instruments Selection of type of treatment Speed power Cool...

Page 18: ...ction of type of treatment Output intensity Operating mode P1 P2 P3 ENDO Cooling status Multifunctional handpiece Air water heating Navigation and operation The following symbols are available for nav...

Page 19: ...eating for air water Off key to switch the heat ing off Tap the type of treatment to unfold a list Select the type of treatment from the list as desired to display the values Tap the Edit key to edit...

Page 20: ...soon as the timer is finished an acoustic signal is issued Tap the timer again to stop the timer Retrieve timer assistant element To start a timer time e g Timer 1 press the Timer 1 key Time on the t...

Page 21: ...ation Feature Selection of the image types that should be displayed x ray intraoral camera Tap the Dental chart key to filter im ages according to teeth This icon is used to save newly recor ded image...

Page 22: ...gle image presentation Two image presentation Four image presentation Six image tile presentation Navigation and operation Icon Feature Change to image viewing mode Return to image overview Confirm ac...

Page 23: ...modes Normal light preset at 5 500 Kelvin and 30 000 Lux corresponding to daylight qual ity COMPOsave mode Enables longer working times for composites by filtering the blue components of the light com...

Page 24: ...mperature Use the Brightness slider to set the brightness to one of 5 levels Set the colour temperature using the Colour temp einstellen Set the brightness and type of dimming Tape the Dim mode key to...

Page 25: ...nt of the sensor for 2 seconds The operating light switches back to normal light mode Turning the laser mode On and Off Tap the Laser key can be added via Settings on home screen The laser mode switch...

Page 26: ...ght can be rotated 45 to the left or 45 to the right Turn the switching ring to the right and it will spring back to its original position If the treatment light is turned to the centre position zero...

Page 27: ...top corresponds to the minimum speed intensity The right stop corresponds to the maximum speed intensity Preselect counterclockwise motor rotation Take motor from the holder The handpiece is active Sl...

Page 28: ...ng device activated When you switch to the CONEXIO menu from another menu the images of the selected patient are displayed until another patient is selected 7 6 8 5 3 Item Name Function U shaped switc...

Page 29: ...ltifunctional handpiece Holder pad non slip mat Handpiece holder Swing arm S table Instrument tray for surgery as sembly kit Intraoral camera Assistant element Connection parts of the suction hose Pat...

Page 30: ...hing The bowl is being rinsed The flushing time can be changed When the rinsing position SP is reached the bowl is rinsed for the complete rinsing time i e the bowl is being wetted Leaving the rinsing...

Page 31: ...an be run in se quence Placing the handpieces in the hygiene centre The cannulas of the three function and multifunctional handpieces must be removed for the cleaning programmes S table Lock the swing...

Page 32: ...nction handpieces in the grey holder and multifunctional handpieces in the black holder of the hygiene centre Place the handpiece hoses of the dentist element in the designated places of the hy giene...

Page 33: ...ning programs Tap the x button to discontinue a cleaning programme Tap the Confirm icon to discontinue the cleaning or tap the x button to continue the cleaning 6 4 Cleaning program After treatment Ru...

Page 34: ...is 2 minutes per instru ment Tap the corresponding button to start the cleaning programme Morning or Even ing The following message is displayed after completion of the cleaning programme After comple...

Page 35: ...ensive germ reduction during prolonged periods of non use During extended periods of non use e g semester breaks at university Weekly clean ing must be run during the time of non use The germ reductio...

Page 36: ...ond full weekly cleaning The unit is now ready for use 6 8 Manual internal cleaning of the suction hoses Note Clean the suction hoses every evening and disinfect them with DEKA SEPTOL Gel daily includ...

Page 37: ...hen changing DEKASEPTOL Gel bottle Turn the device on Remove the cover from the unit base Unscrew the lid of the new DEKASEPTOL gel bottle Take the empty bottle out of the base of the device unscrew t...

Page 38: ...with drain tap Mat no 0 224 6876 The touchscreen shows a status message when the bottle is taken out of the unit In or der to display the No Dekaseptol bottle status message tap first the arrow and th...

Page 39: ...ottle Swing out the empty OXYGENAL 6 bottle from the unit base and pull it down off the adapter The touchscreen shows a status message when the bottle is taken out of the unit In or der to display the...

Page 40: ...6 Hygiene 40 6 11 Check the OXYGENAL 6 concentration Test the standard concentration 0 02 H2O2 200ppm Fill a measuring cup 40 ml with 39 ml water and 1 ml treated water Immerse a Merckoquant Peroxide...

Page 41: ...he following table H2O2 concentra tion Measuring cup Ratio water treated water Value shown on test strip 0 02 200 ppm standard concentra tion 40 ml 39 1 5 mg l 0 05 500 ppm 100 ml 99 1 5 mg l 0 1 1 00...

Page 42: ...ase from Charging to Full is indicated by brief flicker of the display The wireless foot control transmits the user activities to the treatment centre by Bluetooth Back of the foot control Item No Des...

Page 43: ...capacity Foot control status Status display charge status dis play Beep 100 Idle state Foot control is on Flashes green approx 2 second in tervals Active actuation Flashes green approx 200 milli secon...

Page 44: ...t element Inner side cover B E70 Vision Inner side cover A E80 Vision Support cover Backrest Bench Kickplate Seat base Stirrup on foot control Item no Safety shutdown actuated Display LED on the as si...

Page 45: ...shooting Malfunction Cause Remedy Nothing works Main switch is off Turn on main switch Nothing works The main fuse is tripped Unplug the unit from the mains Check and replace if required the main serv...

Page 46: ...on machine or elimin ate the defect The slide valves in the conical sections of the suction hoses are closed Open the slide valve The sieves in the se lective valves are plugged Exchange the sieve The...

Page 47: ...wireless foot control does not re turn to centre posi tion Charge battery 8 3 Additional warning messages Malfunction Cause Remedy A signal is emitted every 10 seconds and a status mes sage is shown T...

Page 48: ...amalgam separator Emergency shut off of the bowl valve only when external suction is installed Call a service technician MOSFET short circuit Turn the device off Commission service technician to carr...

Page 49: ......

Page 50: ...1 011 1004 Fk 20220131 7 en...

Reviews: