Operating Manual
Original Operating Manual
15
The specified maintenance schedules can change as a result of the operating conditions
such as extreme cold, heat and dust or poor ground conditions and this must be taken
into account by the owner.
With other loads, such as fork arms with a length of over 2,400 mm or raised load
centres, amended/shorter maintenance intervals should be agreed by the user with the
manufacturer.
6.3.1 Rotator and flange
Daily
Check all lines, hoses and connections for leakage and damage.
After 50h / every 500h thereafter
Check:
(1, 2) on the fork carriage (3) / flange (4) / slewing ring (5).
(6) and washer (7) on the fork carriage (23.
(8) and limit stops (9) on the fork carriage (3).
Replace loose or damaged screws. Torque the screws as specified in Chapter 6.1
General.