background image

 

 



SAFETY 



This  CARTADIS  product  and 
supplies  are  manufactured  and 
certified 

to 

strict 

safety 

regulations, 

electromagnetic 

regulations 

and 

established 

environmental standards. 

 

 



WARNING! 



Any  unauthorised  alteration, 
which  may  include  the  addition 
of  new  functions  or  connection 
of  external  devices,  may  impact 
the product certification. 
Please  contact  your  CARTADIS 
representative 

for 

more 

information. 

 

 

Warning markings

  

 

All  warning  instructions  marked 
on or supplied with the product 
should be followed. 

 

Electrical supply

 

 

This  product  shall  be  operated 
from  the  type  of  electrical 
supply 

indicated 

on 

the 

product's data plate label. If you 
are not sure  that  your electrical 
supply  meets  the  requirements, 
please consult  your  local  power 
company for advice. 

 

To  disconnect  all  electrical 
power  to  the  product,  the 
disconnect  device  is  the  power 
cord. Remove the plug from the 
electrical outlet. 

 

 

Operator accessible areas

 

 

This  product  has  been  designed 
to  restrict  operator  access  to 
safe areas only. Operator access 
to  hazardous  areas  is  restricted 
with  covers  or  guards  which 
would  have  to  be  removed 
using  a  tool.  Never  remove 
these covers or guards. 

 

Maintenance

 

 

Any 

operator 

product 

maintenance  procedure  will  be 
described 

in 

the 

user 

documentation  supplied  with 
the  product.  Do  not  carry  out 
any 

maintenance 

on 

the 

product  which  is  not  described 
in the customer documentation. 

 

Cleaning your product

 

 

Before  cleaning  this  product, 
unplug  the  product  from  the 
electrical  outlet.  Always  use 
materials  specifically  designated 
for  this  product.  The  use  of 
other  materials  may  result  in 
poor  performance  and  may 
create a hazardous situation. Do 
not  use  aerosol  cleaners;  they 
may  be  flammable    under 
certain circumstances. 

 

 

For 

more 

information 

on 

Environment, Health and safety 
in  relation  to  this  CARTADIS 
product  and  supplies,  please 
contact  the  following  customer 
help lines:

 

Europe: +33 1 48 77 40 60.

 

 
 
 
 

 

 

 
 

The  CE  mark  applied  to  this 
product  symbolises  CARTADIS 
declaration  of  conformity  with 
the 

following 

applicable 

European Union Directives as of 
the dates indicated: 

 

January 1, 1995

 

Council  directive  73/23/EEC, 
amended  by  Council  Directive 
93/68/EEC,  approximation  of 
the  laws  of  the  member  states 
related 

to 

low 

voltage 

equipment

 

January 1, 1996

 

Council  directive  89/336/EEC, 
approximation  of  the  laws  of 
the  member  states  related  to 
electromagnetic compatibility. 

 

A  full  declaration  of  conformity, 
defining  the  relevant  directives 
and  referenced  standards,  can 
be 

obtained 

from 

your 

CARTADIS representative. 

 

 



WARNING! 



In  order  to  allow  this  equipment 
to 

operate  in  proximity 

to 

Industrial,  Scientific  and  Medical 
(ISM)  equipment,  the  external 
radiation from the ISM equipment 
may  have  to  be  limited  or  special 
mitigation measures taken. 

OCT 2020 

Summary of Contents for TCM4

Page 1: ...TCM4 MultiFrequency Card reader User Guide Technical Manual V1 2 ...

Page 2: ...roduct Do not carry out any maintenance on the product which is not described in the customer documentation Cleaning your product Before cleaning this product unplug the product from the electrical outlet Always use materials specifically designated for this product The use of other materials may result in poor performance and may create a hazardous situation Do not use aerosol cleaners they may b...

Page 3: ...eration 4 2 3 1 Memory view 4 2 3 2 Startup sequences 5 2 3 3 LEDs and buzzer status specification 6 3 Configuration 7 3 1 TCM4 parameters 8 3 2 Modification 9 3 2 1 By command lines in application mode 9 3 2 2 By a configuration file in bootloader mode 11 4 Firmware 14 4 1 Upgrading TCM4 firmware 14 OCT 2020 ...

Page 4: ...into the designed shape of the cPad the TCM4 enables the user to be identified by using a card with a solution like Gespage PaperCut etc PC applications entry without error code of a RFID tag enrolment of a user s card in a database secured access to some applications Point of sale connection to the cash registers for loyalty management OEM Cartadis assists its customers by providing a customizati...

Page 5: ...des functions for programming new firmware This means that the bootloader must be entered to program a new firmware Application TCM4 application Storage Storage area where a new firmware file and the configuration file are stored It is accessible from host computer through USB mass storage in bootloader mode Bootloader 200 Kbytes Bootloader The bootloader is the entry point for the firmware after ...

Page 6: ...2 3 2 Startup sequences The diagram on the next page shows the sequences of how bootloader and application are started Valid firmware Available firmware in storage zone OCT 2020 ...

Page 7: ...eps A copy from host computer to storage zone of TCM4 on USB mass storage is in progress Blinks 2 3 times slowly and stays ON A firmware s update is done copy of firmware from storage zone to application zone and firmware verification Blinks every 500ms TCM4 in application mode Normal operation Blinks every 500ms 1 beep Card detected OCT 2020 ...

Page 8: ...t of predefined parameters to be displayed or modified These parameters can be modified or displayed in two different ways from a serial terminal like Putty or from a configuration file The next paragraphs will describe the TCM4 parameters and the way they are configured OCT 2020 ...

Page 9: ...Mhz 0100 iCLASS 13 56Mhz 0400 IZLY complete format 13 56Mhz requires a TCM4 Izly 0800 FELICA 13 56Mhz 1000 IZLY short format 13 56MHz requires a TCM4 Izly 10000 IZLY long format 13 56MHz requires a TCM4 Izly 40000 NFC for Smartphone with CartadisID application 0010 EM Electronic Marin 125Khz 0020 HID Prox 125Khz 0040 HITAG 125Khz 2000 Indala 125Khz 8000 StartProx FFFF FFFF All card types 0000 Lock...

Page 10: ... 0x00 0x00 0x00 0x00 HID parameters hidmode Decoding mode of HID tag 0 normal 26 26 bits mode 254 Mixed mode 26 bits Normal 0 Normal mode hidsite Site code 8 bits in hexadecimal using when hidmode is set to 26 bits mode 0 Miscellaneous debug Enable Disable debug mode With this mode the message sent to the host computer via USB gives extra information about the card technology in form Detected freq...

Page 11: ...t is connected to a PC it declares itself as a USB composite device CDC and HID The serial port of the PC must be configured as below All TCM4 commands are shown in entering help or In the following screen shot the first column indicates whether the parameter can be modified when TCM4 is in application mode For_App bootloader mode For_Boot or whatever the mode For_All ...

Page 12: ...m application mode to bootloader mode you need to enter the command gobootload in a serial terminal like Putty see above Once your TCM4 is in bootloader mode you can read write the parameters of TCM4 by using a configuration file As soon as TCM4 is in bootloader mode it is mounted to the host computer and it behaves like a USB key with the name TCM4 BOOT OCT 2020 ...

Page 13: ...fferent commands to run After the execution of config cmd file you will find 2 files in the TCM4 BOOT directory config done and config log which are the results of all runned commands Hereafter is an example of a configuration file and result file OCT 2020 ...

Page 14: ... TCM4 drive TCM4 BOOT o Delete config done file and config log file o Copy a new config cmd file to the TCM4 BOOT o TCM4 should automatically un mount and re mount itself o If the execution of configuration file was successful you will get a new config done file and config log file Consult config log file to know the result OCT 2020 ...

Page 15: ...4 s firmware the following instructions have to be achieved Navigate to the newly mounted TCM4 TCM4 BOOT Delete TCM4_Firmware_vx x x ctd file Copy a new firmware file to TCM4 BOOT TCM4 should automatically un mount and re mount itself The update was successful if the FwUpdate_Success stt status file is present All the firmware update status are detailed below Status Description FwUpdate_NoFwFile s...

Reviews: