System example
(Symbolic representation)
Terrestrische
Antenne
(Symbolische Darstellung)
EMU 250
(optional)
UAS 584 oder
UAS 585
EMU 250
(optional)
If the required level ratios are observed, a maximum number of three ampli
fi
ers can be operated in
a cascade.
Amplifi er voltage supply
Kathrein ampli
fi
ers are equipped with an innovative powering concept. The ampli
fi
ers can be powered in two ways:
1. Through remote feeding via the coaxial cable of the “H low” connection on a terminal multi-switch
2. Through connection of the optional NCF 18 power supply unit to the “DC” socket (does not include powering of
the feed system!)
Potential equalisation
For potential equalisation use an earthing wire with a cross section of at least
4 mm. The unit is to be earthed using the earthing screw provided on the unit. Each
unit in the reception system must be earthed.
or
Terrestrial
antenna
(Symbolic representation)
• If the inner cable conductor diameter is
greater than 1.2 mm or in case of burr, the
device sockets may be destroyed.
Diameter
0.6-1.2 mm
free of burrs
Max. 2 mm excess
length
Clamping torque max.
3 Nm
(danger of overwinding)