Type
AOI 65
AON 65
AOP 52
AOP 65
Order nr.
212340
212344
212347
212348
Channels
21…65
21…65
21…52
21…65
Gain
dB
7…9
8,5…13
11…15
9,5…15
Reception range
MHz
470…830
470…830
470…726
470…830
Half-power beam width
horiz.°
58…40
57…32
43…26
48…26
vert.°
90…65
68…45
52…32
56…32
Return loss
dB
21…26
22…28
24…30
24…30
Mast clamp range
mm Ø
22…60
Length
mm
360
710
1380
1270
Wind load at 800 N/m
2
N
39
53
108
103
Limit wind load at 1100 N/m
2
N
54
81
148
142
Packing unit/Weight
pc./kg
2/1.9
1/1.7
1/2.3
1/2.2
Pack dimensions
mm
510 x 490 x 75
740 x 520 x 75
890 x 520 x 100
785 x 520 x 100
Type
AOS 32
AOS 65
AOT 65
Order nr.
212349
212352
212353
Channels
21…32
21…65
21…65
Gain
dB
15,5…17
11…17
12…18
Reception range
MHz
470…566
470…830
470…830
Half-power beam width
horiz.°
26…21
43…21
37…18
vert.°
30…23
47…23
39…19
Return loss
dB
27…31
25…32
23…32
Mast clamp width
mm Ø
22…60
Length
mm
2830
2240
2820
Wind load at 800 N/m
2
N
203
179
192
Limit wind load at 1100 N/m
2
N
287
246
263
Packing unit/Weight
pc./kg
1/3.8
1/3.5
1/3.7
Pack dimensions
mm
1080 x 520 x 130
960 x 520 x 130
1080 x 520 x 130
Type
ZSD 48
ZSF 47
ZSF 48
ZSH 47
ZSH 48
ZSH 59
ZSH 62
2
)
Order no.
218380
218385
218381
218386
218394
218382
218383
Length
L/m
2 x 2 = 4
2 x 2,5 = 5
2 x 3 = 6
Diameter
D
1
/D
2
/mm
40/48
40/48
40/48
40/48
40/48
48/60
48/60
Cable insertion inlets
3
–
3
–
3
5
5
Quality class (steel)
St 52
St 37
St 52
St 37
St 52
St 52
St 52
Wall thickness in clamping area
mm
2.5
2
2.5
2
2.5
2.5
4.5
Allowed bending moment
1
)
5.0 m
–
–
–
320
850
1150
1950
(1150)
Useful length at 800 N/m
2
4.0 m
–
500
1040
430
960
1280
2120
(1280)
3.0 m
1170
540
1080
–
–
–
–
Allowed bending moment
1
)
5.0 m
–
–
–
160
700
900
1700 (900)
Useful length at 800 N/m
2
4.0 m
–
390
920
300
840
1080
1960 (1080)
3.0 m
1110
480
1000
–
–
–
–
Packing unit/Weight
pc./kg
1/11.4
1/11.3
1/14.2
1/13.1
1/17.8
1/20.5
1/37.5
Mast tables
Antenna technical data
935.543/A00/800/3.3e Subject no technical modifications.
KATHREIN-Werke KG · Anton-Kathrein-Straße 1–3 · Postfach 10 04 44 · D-83004 Rosenheim · Deutschland · Telefon (0 80 31) 18 40 · Telefax (0 80 31) 18 43 06
Internet: http://www.kathrein.de
1
) The maximally allowed moment on the clamping area is dependant on the used free lengths. The pipe’s wind loading has already been considered. The bold-printed
values are valid for normal wind loads (q= 800 N/m
2
). At higher wind loads (1100 N/m
2
) the reduced values should be used.
According to DIN EN 50083-1 the minimal mast clamp length must be 1/6 of the overall mast length.
2
) The technical data have been calculated as per the calculation base in DIN 4131. Should the sum of the antenna wind load moments exceed the values given in
brackets (= 1650 Nm on clamp point), the as per DIN EN 80053-1 a static check has to be conducted.