background image

Type

AOI 65

AON 65

AOP 52

AOP 65

Order nr.

212340

212344

212347

212348

Channels

21…65

21…65

21…52

21…65

Gain

dB

7…9

8,5…13

11…15

9,5…15

Reception range

MHz

470…830

470…830

470…726

470…830

Half-power beam width

horiz.°

58…40

57…32

43…26

48…26

vert.°

90…65

68…45

52…32

56…32

Return loss

dB

21…26

22…28

24…30

24…30

Mast clamp range

mm Ø

22…60

Length

mm

360

710

1380

1270

Wind load at 800 N/m

2

N

39

53

108

103

Limit wind load at 1100 N/m

2

N

54

81

148

142

Packing unit/Weight

pc./kg

2/1.9

1/1.7

1/2.3

1/2.2

Pack dimensions

mm

510 x 490 x 75

740 x 520 x 75

890 x 520 x 100

785 x 520 x 100

Type

AOS 32

AOS 65

AOT 65

Order nr.

212349

212352

212353

Channels

21…32

21…65

21…65

Gain

dB

15,5…17

11…17

12…18

Reception range

MHz

470…566

470…830

470…830

Half-power beam width

horiz.°

26…21

43…21

37…18

vert.°

30…23

47…23

39…19

Return loss

dB

27…31

25…32

23…32

Mast clamp width

mm Ø

22…60

Length

mm

2830

2240

2820

Wind load at 800 N/m

2

N

203

179

192

Limit wind load at 1100 N/m

2

N

287

246

263

Packing unit/Weight

pc./kg

1/3.8

1/3.5

1/3.7

Pack dimensions

mm

1080 x 520 x 130

960 x 520 x 130

1080 x 520 x 130

Type

ZSD 48

ZSF 47

ZSF 48

ZSH 47

ZSH 48

ZSH 59

ZSH 62

2

)

Order no.

218380

218385

218381

218386

218394

218382

218383

Length

L/m

2 x 2 = 4

2 x 2,5 = 5

2 x 3 = 6

Diameter

D

1

/D

2

/mm

40/48

40/48

40/48

40/48

40/48

48/60

48/60

Cable insertion inlets

3

3

3

5

5

Quality class (steel)

St 52

St 37

St 52

St 37

St 52

St 52

St 52

Wall thickness in clamping area

mm

2.5

2

2.5

2

2.5

2.5

4.5

Allowed bending moment

1

)

5.0 m

320

850

1150

1950 

(1150)

Useful length at 800 N/m

2

4.0 m

500

1040

430

960

1280

2120 

(1280)

3.0 m

1170

540

1080

Allowed bending moment

1

)

5.0 m

160

700

900

1700 (900)

Useful length at 800 N/m

2

4.0 m

390

920

300

840

1080

1960 (1080)

3.0 m

1110

480

1000

Packing unit/Weight

pc./kg

1/11.4

1/11.3

1/14.2

1/13.1

1/17.8

1/20.5

1/37.5

Mast tables

Antenna technical data

935.543/A00/800/3.3e    Subject no technical modifications.

KATHREIN-Werke  KG · Anton-Kathrein-Straße 1–3 · Postfach 10 04 44 · D-83004 Rosenheim · Deutschland · Telefon (0 80 31) 18 40 · Telefax (0 80 31) 18 43 06

Internet: http://www.kathrein.de

1

) The maximally allowed moment on the clamping area is dependant on the used free lengths. The pipe’s wind loading has already been considered. The bold-printed

values are valid for normal wind loads (q= 800 N/m

2

). At higher wind loads (1100 N/m

2

) the reduced values should be used.

According to DIN EN 50083-1 the minimal mast clamp length must be 1/6 of the overall mast length.

2

) The technical data have been calculated as per the calculation base in DIN 4131. Should the sum of the antenna wind load moments exceed the values given in

brackets (= 1650 Nm on clamp point), the as per DIN EN 80053-1 a static check has to be conducted.