Cabling

1.  Connect a potential equalisation wire (Cu, ≥ 4 mm

2

) to the earthing screw; see 

 in Fig. 1, P. 3.

2.  Connect an Ethernet cable

1)

 to the RJ45 socket on the computer, if required, by means of a switch or router; see 

Fig. 4, P. 5. The head-end will now function as the 

master

.

3.  If UFOmini devices are connected to a system via UFOlink, please cascade each additional device with a USB 2.0 

cable according to the following specifications (Fig. 4). In this case:

 

Each additional head-end functions as a 

slave

 which is controlled by the master via the USB cable.

 

The USB cable must have a type A plug on one end and a type B plug on the other end.

 

The plugs must be inserted into the master and slave at the appropriate UFO link interface ports (

 in Fig. 1).

 

The cascading up to four head-ends permits simultaneous access to all devices via 

a single

 IP connection, and 

also allows system functions that apply to both devices, such as common NIT generation incl. LCN.

 

Only head-ends of the same type can be connected by USB. 

4.  Connect the RF signal cables for the antenna, cable network and output to the head-ends; see 

 and 

 in 

Fig. 1, P. 3.  
Make sure the input and output cables are correctly assigned to the master and the slave.

2)

 

5.  It is recommended that each unused RF input and output is terminated with a 75-Ω resistor such as the EMK 03 from 

Kathrein.

6.  Check that the supply voltage matches the particulars on the rating plate, then connect the head-ends to the power 

supply.

 

The head-ends will start up and the status LED will show the operating status

3)

.

1)

  CAT5 or higher is recommended, crossed over for a direct connection to the computer and not crossed over for connections by 

means of a switch/router.

2)

  Connect the RF signal cables for the antenna and/or cable network to the master. The RF signal cables regulate the signals 

which are output from the master. The same applies to the slave, where present. Compilation of the signals is performed by the 
USW 800.

3)

  see also 

LEDs and reset button

, P. 3.

USB 

Type A

USB

Type B

USW 800

IN

EBC 02/G

21610084

3,9 dB

5-1218 MHz

3,9 dB

+10dB

USB 2.0 cable*

Ethernet

Output

Output

Switch

EBC 02/G*

UFOmini Master

UFOmini Slave

* Available as accessory

Fig. 4:  Cabling

Summary of Contents for UFO Mini 87-18

Page 1: ...in Eingang für beide Multistandard Frontends Spannungsversorgung für zwei LNB und eine aktive Antennen Alle Übertragungsparameter sind mit der Konfigu rationssoftware USW 800 einstellbar Fernwartung und konfiguration Umfangreiche Basisband Signalverarbeitung mit z B Programmfilterfunktionalität NIT LCN Bis zu vier Geräte können in einem Systemverbund gemeinsam administriert und konfiguriert werden...

Page 2: ...ht an die Stromversorgung angeschlossen sein Anlage sofort von der Stromversorgung trennen wenn das Gerät und oder angeschlossene Leitungen beschädigt sind Anlage nicht wieder einschalten bevor das Gerät vom Händler oder Hersteller repariert wurde angeschlossene Leitungen von einer Fachkraft repariert wurden Gehäuse nicht öffnen und Gerät nicht verändern Andernfalls erlöschen die Garantie und die ...

Page 3: ...r Verkabeln S 5 3 Wenn die Kopfstelle der Master ist mehr dazu unter Verkabeln S 5 LEDs und Reset Taste Master LED grün Kopfstelle ist Master aus Kopfstelle ist Slave Status LED grün OK grün blinkend Softwareupdate wird durchgeführt rot Fehler orange Kopfstelle startet orange blinkend Kopfstelle wird von der Konfigurations software USW 800 identifiziert Reset Taste Drücken 5 s1 Kopfstelle startet ...

Page 4: ...recht schwer entzündlich und ausreichend stabil Um das Gerät ist die freie Luftzirkulation möglich der Freiraum gemäß Abb 2 ist vorhanden Die zulässigen Umgebungsbedingungen werden eingehalten siehe Technische Daten S 6ff Das Gerät ist nicht Tropf oder Spritzwasser ausgesetzt Der Netzstecker ist gut zugänglich und leicht zieh steckbar So montieren Sie die Kopfstelle 1 Montieren Sie den Wandhalter ...

Page 5: ... USB verbunden werden 4 Schließen Sie die HF Signalleitungen für Antenne Kabelnetz und Ausgang an die Kopfstellen an siehe und in Abb 1 S 3 Achten Sie darauf die Ein und Ausgangsleitungen dem Master und dem Slave richtig zuzu ordnen 2 5 Es wird empfohlen nicht benutzte HF Ein Ausgänge mit einem 75 Ω Widerstand zu terminieren z B mit dem EMK 03 von Kathrein 6 Stellen Sie sicher dass die Versorgungs...

Page 6: ...n V kHz 14 18 0 22 Fernspeisestrom für LNB mA max 250 an F Buchse Nr 3 und 7 max 60 an F Buchse Nr 1 2 4 5 6 8 Fernspeisestrom für aktive Antenne 5 V mA 50 an F Buchse Nr 9 Frontend DVB S 2 16 x DVB S 2 T 2 C 2x Frequenzraster MHz 1 Eingangspegelbereich DVB S 2 dBµV 45 90 Eingangspegelbereich DVB S 2 T 2 C dBµV 55 100 Zulässige Pegeldifferenz dB 20 Demodulation DVB S Standard EN 300 421 Frequenzbe...

Page 7: ... 5 6 7 8 Konstellation QPSK 16 QAM 64 QAM 256 QAM Demodulation DVB C Standard EN 300429 ITU J 83 Annex A C Frequenzbereich MHz 48 858 Eingangssymbolrate MS s 1 7 2 Konstellation QAM 4 16 32 64 128 256 MPEG TS Prozessor Programmfilter PSI SI Bearbeitung Cable NIT LCN PCR Korrektur CAT PID SID Remapping Stuffing automatisch Modulator Ausgangskanäle 18 x DVB C J 83A Konstellation 16 32 64 128 256 QAM...

Page 8: ...tausgang Testbuchse 1 x F Connector 75 Ω Pegel relativ zum Ausgang dB 25 Systemdaten Leistungsaufnahme W 34 38 Zulässige Umgebungstemperatur C 0 45 Abmessungen H x B x T mm 97 118 x 350 x 244 inkl Wandhalterung Gewicht kg ca 4 1 Nur Full Band Frontend Eingänge 1 8 2 Siehe QPSK Reparatur und Austausch Wenn Sie nach dem Lesen der Anleitung unbeantwortete Fragen haben oder ein Problem nicht lösen kön...

Page 9: ...ti switches Power supply for two LNB and one active antenna All functionalities and parameters can be set using the USW 800 configuration software Remote maintenance and configuration Comprehensive baseband signal processing such as channel filter functionality NIT LCN Up to four devices can be administered and configured together in a system network NIT LCN Channel allo cation No fan therefore no...

Page 10: ...mmediately disconnect the system from the power supply Do not switch the system on again until the device has been repaired by the dealer or manufacturer and the cables connected have been repaired by a competent person Do not open the casing and do not modify the device Otherwise the guarantee and warranty will become void Never cover the cooling ribs or the air circulation openings Do not modify...

Page 11: ...head end is the slave see below for more info Cabling P 5 3 If the head end is the master see below for more info Cabling P 5 LEDs and reset button Master LED green the head end is the master off the head end is a slave Status LED green OK green flashing software update in progress red error orange head end starting orange flashing head end is being identified by the USW 800 configuration software...

Page 12: ...owing conditions The installation surface must be not readily flammable and must be sufficiently stable To allow free circulation of air around the device the clearances shown in Fig 2 must be ensured The permissible environmental conditions must be satisfied see Technical data P 6ff The device must not be exposed to dripping or splashing water The power plug must be easily accessible and be easy ...

Page 13: ...cted by USB 4 Connect the RF signal cables for the antenna cable network and output to the head ends see and in Fig 1 P 3 Make sure the input and output cables are correctly assigned to the master and the slave 2 5 It is recommended that each unused RF input and output is terminated with a 75 Ω resistor such as the EMK 03 from Kathrein 6 Check that the supply voltage matches the particulars on the...

Page 14: ...0 22 Remote feed current for LNB mA max 250 at F socket no 3 and 7 max 60 at F socket nos 1 2 4 5 6 8 Remote feed current for active antenna 5 V mA 50 at F socket no 9 Frontend DVB S 2 16 x DVB S 2 T 2 C 2 x Frequency grid MHz 1 Input level range DVB S 2 dBµV 45 90 Input level range DVB S 2 T 2 C dBµV 55 100 Permissible level difference dB 20 Demodulation DVB S Standard EN 300 421 Frequency range ...

Page 15: ... Constellation QPSK 16 QAM 64 QAM 256 QAM Demodulation DVB C Standard EN 300429 ITU J 83 Annex A C Frequency range MHz 48 858 Input symbol rate MS s 1 7 2 Constellation QAM 4 16 32 64 128 256 MPEG TS processor Channel filter PSI SI processing cable NIT LCN PCR correction CAT SID remapping Stuffing automatic Modulator Output channels 18 x DVB C J 83A Constellation 16 32 64 128 256 QAM MS s 2 25 7 2...

Page 16: ...ket 1 x F connectors 75 Ω Level relative to the output dB 25 System data Power consumption W 34 38 Permissible ambient temperature C 0 45 Dimensions H x W x D mm 97 118 x 350 x 244 incl wall support Weight kg approx 4 1 Only full band frontend inputs 1 8 2 Please refer to QPSK Repair and Replacement If after having read this manual you still have unanswered questions or cannot solve a problem cont...

Reviews: