Configuration manual Reader
24
Modifications, misprints and errors excepted.
English
2.
Description of the configuration parameters
2.8.4.
“MinChannelWaitTime”
Characteristics:
available from firmware:
v1.32.00
Data type:
Word (16-bit)
Unit:
milliseconds
Value range:
0-65535
Description:
This configuration parameter for the “Special” communications standard specifies how long the reader must wait
before returning to a channel after its maximum exposure time (“MaxChannelTime”) has elapsed.
2.8.5.
“FirstChannel”
Characteristics:
available from firmware:
v1.32.00
Data type:
Byte (8-bit)
Unit:
–
Value range:
0-255
Description:
This configuration parameter for the “Special” communications standard specifies the first channel to be used for this
communications standard. The frequency of the channel is determined by the following formula:
2.8.6.
“LastChannel”
Characteristics:
available from firmware:
v1.32.00
Data type:
Byte (8-bit)
Unit:
–
Value range:
0-255
Description:
This configuration parameter for the “Special” communications standard specifies the last channel to be used for this
communications standard. The frequency of the channel is determined by the following formula:
f
=
“CenterFreqCH
0
” + “FirstChannel” * “ChannelWidth”
f
=
“CenterFreqCH
0
” + “LastChannel” * “ChannelWidth”