2 / 2
936.4998/–/VMPT/0715/GB – Technical data subject to change!
www.kathrein.com
KATHREIN-Werke KG • Anton-Kathrein-Straße 1 – 3 • 83004 Rosenheim • Germany • Phone +49 8031 184-0 • Fax +49 8031 184-306
Electronic equipment is not domestic waste - in accordance with directive 2002/96/EC OF THE EUROPEAN
PARLIAMENT AND THE COUNCIL dated 27th January 2003 on used electrical and electronic appliances, it
must be disposed of properly.
At the end of its service life, take this unit for disposal to an appropriate official collection point.
The elevation indicator and the receiver are connected by means of a cable. The HDS 66 control unit has two F-type
female connectors, i.e. two cables are necessary. There are two options to connect the HDS 66 to the receiver and the
HDZ 60/66 elevation indicator:
1. Cut the cable between the receiver and the elevation indicator and attach the provided F-type connectors onto both
ends of the cable, see
Attach the F-type connectors.
NOTICE
Make sure that the cable has a solid inner conductor, otherwise it is not possible to insert the inner conductor
into the F-type female connector of the HDS 66 after the F-type connectors have been attached.
2. Connect the HDS 66 control unit and the HDZ 60/66 elevation indicator using the cable at hand. Connect the receiver
and the HDS 66 using an additional coaxial cable (not included in the scope of delivery).
Attach the F-type connectors
Only use the enclosed F-type connectors. Do not use any tools to attach the F-type connectors, tighten them hand-
tight.
NOTICE
Risk of short circuit!
Material damage due to contact between the wires of the braided shield and the inner conductor.
►
When attaching the F-type connectors, make sure that there is no contact between the wires of the braided
shield and the inner conductor.
1. Remove 10 mm from the outer plastic jacket
①
. Cut into it carefully so as not
to damage the braided shield
②
.
2. Pull the braided shield
②
back.
3. Remove 7 mm dielectric and aluminium foil
③
from the inner conductor
④
.
4. Screw the F-type connector
⑤
onto the end of the cable until it sits tightly.
② ③ ④
①
⑤
Connect the cable
Connect the receiver to the input F-type female connector and the HDZ 60/66 to the output F-type female connector:
Receiver
HDS 66
HDZ 60/66
BAS 60/66