Step 3: Check the receiver settings
If still no reception can be obtained, check the receiver settings once again:
There is a red LED on the multi-switch, which flashes briefly when the switch-over
command is received from the receiver. If the receiver then receives no signal from the
multi-switch, it generally sends out a command every 1 to 3 seconds. The red LED then
flashes on each occasion. If the receiver does not repeat the commands automatically,
it must be "zapped" manually.
Problem
Red
LED
Possible cause
Solution
Continuous message
"Poor or no signal"
Off
Receiver not in
single cable mode
Check the tuner settings
Wrong PIN code
Check the PIN code number
or deactivate the PIN feature
Flas-
hing
UB and frequency
do not match
Adjust the tuner settings.
The UBs and their associated frequen-
cies are listed on the multi-switch or under
"Technical Data"
(Caution: The SCR number is one
less than the UB number)
Short message:
"Poor or no signal"
or image breaks in at
regular intervals
Flas-
hing
Another subscriber
is accessing the
same UB to
Check the menu settings of all connected
receivers. Check unique assignment
of frequencies and UBs.