background image

2-Port Antenna

Frequency Range

Dual Polarization

Half-power Beam Width

Integrated replaceable Remote Control Unit

Adjustable Electrical Downtilt

R1

R1

2-Port Antenna iRCU 698–894 65° 16dBi 0°–10°T

Type No.

80010735

V01

A) Antenna specifi cations

R1, connector  1– 2

R1, connector  1– 2

698 – 894

Frequency range

MHz

698 – 806

824 – 894

Polarization

°

+45, –45

+45, –45

Gain

dBd

dBi

13.35

15.5

13.85

16

Horizontal Pattern:

Half-power beam width

°

67

65

Front-to-back ratio

dB

Copolar:   > 30
Average: 35

Copolar:   > 30
Average: 35

Cross polar ratio
Maindirection

Sector

±60°

dB

Typically: > 25

> 11, Avg. 15

Typically: > 25

> 11, Avg. 15

Vertical Pattern:

Half-power beam width

°

11.3

10

Electrical tilt

°

0 – 10, continuously adjustable

Min. sidelobe suppression for 
fi rst sidelobe above main beam:
Average:

° T
dB
dB

0 ... 5 ... 10

16 ... 17 ... 17
16 ... 19 ... 20

0 ... 5 ... 10

18 ... 17 ... 16
20 ... 20 ... 20

Impedance

Ω

50

VSWR

< 1.5

Isolation, between ports

dB

> 30

Intermodulation IM3

dBc

< –150 (2 x 43 dBm carrier)

Max. power per input

W

500 (at 50 °C ambient temperature)

698 – 894

X

65°

iRCU

0°–10°

B) iRCU specifi cations (86010149)*

Field replaceable without dismantling the antenna

Logical interface ex factory

1)

3GPP/AISG 2.0

Protocols

Compliant to AISG 1.1 and 3GPP/AISG 2.0

Hardware interface

2)

2 x 8pin connector acc. IEC 60130-9;
according to AISG:
– iRCU in (male): Control / Daisy chain in
– iRCU out (female): Daisy chain out

Power supply

10 ... 30 V

Power consumption

< 1 W (stand by)

< 8.5 W (motor activated)

Adjustment time (full range)

40 sec.

Adjustement cycles

> 50,000

Certifi cation

CE, 

3)

* See mounting instructions and warnings.

1)

  The protocol of the logical interface can be switched from 3GPP/AISG 2.0 to AISG 

1.1 and vice versa with a vendor specifi c command. Start-up operation of the iRCU 
86010149 is possible in a RET system supporting AISG 1.1 or supporting 3GPP/AISG 
2.0 after performing a layer 2 reset before address assignment. The protocol can also 
be changed as follows: 

AISG 1.1 to 3GPP:

 Enter „3GPP“ into the additional data fi led 

„Installer’s ID“ and perform a layer 7 reset or a power reset. 

3GPP to AISG 1.1:

 Enter 

„AISG 1“ into the additional data fi eld „Installer’s ID“ and perform a layer 2 reset or a 
power reset. After switching the protocol any other information can be entered into the 
„Installer’s ID“ fi eld.

2)

  The tightning torque for fi xing the connector must be 0.5 – 1.0 Nm (‘hand-tightened’). The 

connector should be tightened by hand only or using the torque screwdriver (85010080) 
as described in the connecting cable data sheet (86010007, ...)!

3)

  Tested to comply with FCC Standards. This device complies with part 15 of the FCC 

Rules. Operation is subject to the following two conditions: (1) This device may not cause 
harmful interference, and (2) this device must accept any interference received, including 
interference that may cause undesired operation.

698 – 894

–45°

7-16

698 – 894

+45°

7-16

iRCU

in

out

8pin

male

8pin

female

80010735

V01

   Page 1 of 2

936.4273/

b

.1

     Subject to alteration.

Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082

Phone: 214.238.8800    Fax: 214.238.8801    Email: [email protected]

All specifications are subject to change without notice.

The latest specifications are available at www.kathreinusa.com

Downloaded from

Arrow.com.

Summary of Contents for 80010735V01

Page 1: ...ing instructions and warnings 1 The protocol of the logical interface can be switched from 3GPP AISG 2 0 to AISG 1 1 and vice versa with a vendor specific command Start up operation of the iRCU 86010149 is possible in a RET system supporting AISG 1 1 or supporting 3GPP AISG 2 0 after performing a layer 2 reset before address assignment The protocol can also be changed as follows AISG 1 1 to 3GPP E...

Page 2: ...Max wind velocity km h mph 241 150 Height width depth mm inches 1934 303 99 76 1 11 9 3 9 Category of mounting hardware H Heavy Weight kg lb 14 16 clamps incl 30 9 35 3 clamps incl Packing size mm inches 2136 x 317 x 127 84 1 x 12 5 x 5 Scope of supply Panel 1 unit of iRCU and 2 units of clamps 42 115 mm 1 7 4 5 inches diameter R1 Material Reflector screen Weather proof aluminum Radiator Tin plate...

Page 3: ...ppropriate standard of the Primary before installation Please contact Kathrein for further information 2 The tightning torque for fixing the connector must be 0 5 1 0 Nm hand tightened The connector should be tightened by hand only Standards EN 60950 1 Safety EN 55022 Emission EN 55024 Immunity ETS 300019 1 4 Environmental Certification CE FCC15 107 class B Scope of supply Integrable Remote Contro...

Page 4: ...al load imposed on an antenna by wind at maximum velocity Wind loads are calculated according to DIN 1055 4 Extraordinary operating conditions such as heavy icing or exceptional dynamic stress e g strain caused by oscillating support structures may result in the breakage of an antenna or even cause it to fall to the ground These facts must be considered during the site planning process The install...

Page 5: ...s The additional nuts supplied are only meant as spares All dimensions in mm and inches 152 5 98 100 3 94 40 1 57 72 2 83 35 1 38 64 2 52 125 4 92 40 1 57 20 25 0 79 0 98 42 115 1 65 4 53 M10 MA 25 Nm M8 MA 20 Nm 20 25 0 79 0 98 Kathrein USA Greenway Plaza II 2400 Lakeside Blvd Suite 650 Richardson TX 75082 Phone 214 238 8800 Fax 214 238 8801 Email info kathrein com All specifications are subject ...

Page 6: ...control cables Warning Take care that the iRCU does not fall from the antenna housing when the retaining screw is not tightened The falling iRCU can cause injury or death and may permanently damage equipment For daisy chain operation remove the protection cap and attach a control cable to interconnect with the daisy chain input of the next iRCU Please note Do not remove the protection cap on the d...

Page 7: ...rench according to the manufacturers guidelines Ventilation hole 7 16 female iRCU Description of bottom end cap Single band Antennas with iRCU Dual band Antennas with iRCU Ventilation hole 7 16 female iRCU Kathrein USA Greenway Plaza II 2400 Lakeside Blvd Suite 650 Richardson TX 75082 Phone 214 238 8800 Fax 214 238 8801 Email info kathrein com All specifications are subject to change without notic...

Reviews: