background image

Integrable Remote Control Unit (iRCU)

936.4054/b

.1

     Subject to alteration.

Page 2 of 2   

86010149

Please note: 

 Additional grounding of the iRCU is not required if the iRCU is fi xed to an antenna with proper  grounding. 
Please assure that grounding of the antenna has been carried out according to all relevant local  regulations.

 

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operation.

Please note: 

As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point 
out certain risks that may arise when products are used under extraordinary operating conditions.

The mechanical design is based on the environmental conditions as stipulated in ETS 300 019-1-4 and thereby respects 
the static mechanical load imposed on an  antenna by wind at maximum velocity. Wind loads are calculated according to 
DIN 1055-4. Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g. strain caused by 
oscillating support structures), may result in the breakage of an antenna or even cause it to fall to the ground. These facts 
must be considered during the site planning process.

The installation team must be properly qualifi ed and also be familiar with the relevant national safety regulations.
The details given in our data sheets have to be followed carefully when installing the antennas and accessories.
The limits for the coupling torque of RF-connectors, recommended by the connector manufacturers must be obeyed.

Any previous datasheet issues have now become invalid.

Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082

Phone: 214.238.8800    Fax: 214.238.8801    Email: [email protected]

All specifications are subject to change without notice.

The latest specifications are available at www.kathreinusa.com

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for 80010735V01

Page 1: ...ing instructions and warnings 1 The protocol of the logical interface can be switched from 3GPP AISG 2 0 to AISG 1 1 and vice versa with a vendor specific command Start up operation of the iRCU 86010149 is possible in a RET system supporting AISG 1 1 or supporting 3GPP AISG 2 0 after performing a layer 2 reset before address assignment The protocol can also be changed as follows AISG 1 1 to 3GPP E...

Page 2: ...Max wind velocity km h mph 241 150 Height width depth mm inches 1934 303 99 76 1 11 9 3 9 Category of mounting hardware H Heavy Weight kg lb 14 16 clamps incl 30 9 35 3 clamps incl Packing size mm inches 2136 x 317 x 127 84 1 x 12 5 x 5 Scope of supply Panel 1 unit of iRCU and 2 units of clamps 42 115 mm 1 7 4 5 inches diameter R1 Material Reflector screen Weather proof aluminum Radiator Tin plate...

Page 3: ...ppropriate standard of the Primary before installation Please contact Kathrein for further information 2 The tightning torque for fixing the connector must be 0 5 1 0 Nm hand tightened The connector should be tightened by hand only Standards EN 60950 1 Safety EN 55022 Emission EN 55024 Immunity ETS 300019 1 4 Environmental Certification CE FCC15 107 class B Scope of supply Integrable Remote Contro...

Page 4: ...al load imposed on an antenna by wind at maximum velocity Wind loads are calculated according to DIN 1055 4 Extraordinary operating conditions such as heavy icing or exceptional dynamic stress e g strain caused by oscillating support structures may result in the breakage of an antenna or even cause it to fall to the ground These facts must be considered during the site planning process The install...

Page 5: ...s The additional nuts supplied are only meant as spares All dimensions in mm and inches 152 5 98 100 3 94 40 1 57 72 2 83 35 1 38 64 2 52 125 4 92 40 1 57 20 25 0 79 0 98 42 115 1 65 4 53 M10 MA 25 Nm M8 MA 20 Nm 20 25 0 79 0 98 Kathrein USA Greenway Plaza II 2400 Lakeside Blvd Suite 650 Richardson TX 75082 Phone 214 238 8800 Fax 214 238 8801 Email info kathrein com All specifications are subject ...

Page 6: ...control cables Warning Take care that the iRCU does not fall from the antenna housing when the retaining screw is not tightened The falling iRCU can cause injury or death and may permanently damage equipment For daisy chain operation remove the protection cap and attach a control cable to interconnect with the daisy chain input of the next iRCU Please note Do not remove the protection cap on the d...

Page 7: ...rench according to the manufacturers guidelines Ventilation hole 7 16 female iRCU Description of bottom end cap Single band Antennas with iRCU Dual band Antennas with iRCU Ventilation hole 7 16 female iRCU Kathrein USA Greenway Plaza II 2400 Lakeside Blvd Suite 650 Richardson TX 75082 Phone 214 238 8800 Fax 214 238 8801 Email info kathrein com All specifications are subject to change without notic...

Reviews: