3 / 16
Mounting
Transmitter (OSC 100 micro) and receiver (OEC 40 micro or OEC 44 micro) can be mount-
ed using 4 wood screws, self-tapping screws or plug screws (thread diameter 4.5 ... 5
mm; head diameter ≥ 9 mm; screw length ≥ 20 mm; round or cylinder head). The screws
required for mounting are not included.
H
low
V
low
H
high
V
high
T
err.
opt
on
F
ibre
H
low
V
low
H
high
V
high
T
err.
14V
max.200mA
T
err.
H
high
Test
205500005
LASER
CLASS 1M
Risk of material damage to the device!
If the inner cable conductor diameter is more than 1.2 mm, or if burring is
present, the device sockets may be destroyed.
Max. 2 mm
excess length
Clamping torque
max. 3.4 Nm
(danger of over-
winding)
Diameter
0.6 - 1.2 mm free of burrs
Equipotential bonding terminal
The devices must be connected to the equipotential bonding of the antenna installation as
per EN 60728-11.