14 / 16
• We recommend using the CAS 90 as the minimum parabolic refl ector
size. In order to achieve optimum signal quality in larger systems, the
CAS 120 should be used.
• All unused coaxial connectors must be terminated with EMK 03, with
the exception of the 4 SAT inputs from OSC 100 micro, which due
to DC voltage must be terminated with EMK 05. All unused optical
connectors of the optical network must be terminated with the OTC 1.
• The integrated AGC of the OSC 100 micro optical transmitters ensures
a constant optical output level independent of the number of digital
terrestrial TV channels or the number of transmitted SAT transponders.
The signal levels on the RF outputs of the OEC 40 micro/OEC 44 micro
optical receivers are therefore dependent on the number of transmitted
digital TV channels or SAT transponders.
• If an additional multi-switch is to be installed after the OEC 44 micro, a
WFS 55 feed-in diplexer must be connected between the OEC 44 micro
and the multi-switch.
Branch diagram, split into 8 optical blocks
As shown in the “CLIKulator” program (http://clikulator.com/kathrein)