EN
762.885 Z05 2012 coolcept_fleX, coolcept³_fleX
19
Inverter, 1 phase
Cable cross section
AC cable
Power loss
(with 10 m cable length)
Circuit breaker
StecaGrid 4611_2
2.5 mm²
56 W
B25
4.0 mm²
35 W
StecaGrid 5011_2
2.5 mm²
64 W
B25
4.0 mm²
40 W
Inverter, 3-phase
Cable cross section
AC cable
Power loss
(with 10 m cable length)
Circuit breaker
StecaGrid 3213
2.5 mm²
4 W
B16
4.0 mm²
3 W
StecaGrid 4013
2.5 mm²
7 W
B16
4.0 mm²
4 W
StecaGrid 5013
2.5 mm²
11 W
B16
4.0 mm²
7 W
StecaGrid 6013
2.5 mm²
14 W
B16
4.0 mm²
8 W
5.3.3 Assembling the AC plug
NOTE
If the instructions of the plug manufacturer are not followed when connecting
the AC plug, the cable and the device may be damaged.
►
Protect plug from bending loads.
►
Do not use plug connector for interruption of current.