27
Remove the connecting rod with slider assembly from the eccentric. Use a flat chisel to lift the
connecting rod
Slide the slider out of the sleeve
Clean the parts with dry cloth. The slider can be cleaned with a soft scotch brite that does not scratch
the surface.
Inspect the parts for any damage and wear. In case of damage or excessive wear install a new drive
service kit (Art no 8019114).
Reassembly
:
Push the small pin in the housing until it is flush with the outer side.
Lubricate the needles of the needle bearing with grease.
Put the sleeve with the bronze bushing first onto the slider. It is not necessary to lubricate as the
bronze bushing is oil impregnated. Push the wiper over the edge while turning the sleeve. Turn the
hole of the sleeve to the side where the needle bearing is not flush with the connection rod. Align it
with the cross holes of the slider.
Place the needle bearing of the connection rod with the jutting side first onto the eccentric. Align the
hole in the sleeve with the pin in the housing and push it back to the housing.
Place the housing front back to the drive assembly. Insert the bolts and tighten it with 25 Nm.
Connect the drive to the power source and check if the drive runs smooth. If it does not run smooth
disassemble the drive again and correct the fault.
Assemble the drive unit to the pump according to the instruction in section “Seal Replacement,
Reassembly”.
flush
Figure R-12
aligned
push
Figure R-13