SETTINGS ADJUSTMENT

RANGE ADJUSTMENT

The sensor range is the range an object can be away from the sensor in order to 
activate the faucet. The sensor is factory preset. If necessary, it can be adjusted as 
follows:

Adjusting the sensor range manually:

1.   Disconnect the battery or switch off the electricity supply to the sensor.

2.   For Nara Q, make a short circuit between the (+) and the (-) connections of the
   sensor. A screw driver or any conductive material can be used to make this  

 

 

short circuit. Alternatively and for Nara QE, activate the sensor three or four times 

 

after disconnecting the power supply.

 

Do not make a short circuit on the power supply or on the sensor when the power  

 

supply is connected to the sensor.

3.   Reconnect the power supply to the sensor.

4.   To enter into the adjusting mode, put your hand in  
 

front of the sensor at a distance of 2 “(5cm) within 

 

5 seconds from the re-connection of the power  

 supply.
 

Note: If you will not put your hand in front of the  

 

sensor after connecting thepower supply, the sensor  

 

will not enter into the adjusting mode and the    

 

previous adjustment will continue.

5.   When the sensor enters into the adjusting mode  
 

and  your hand is in front of the sensor, the red light  

 

in front of the sensor will flash slowly.

6.   Keep your hand in front of the sensor until the slow flashing changes to quick 
 

flashing, At this point move your hand to the required distance from the sensor and  

 

wait until the red light will stop flashing.

7.   When the red light has turned off, the sensor is adjusted to the required distance.

8.   Check the distance you have set and if it is not satisfactory, repeat the procedure. 

SECURITY TIME: The Security time, prevents continuous flushing of water 
due to reflections or vandalism. By default, if the sensor is covered for 
more than 90 seconds the water flow will shut automatically. To resume 
regular operation any obstruction must be removed.
Press the SEC button. Wait until a quick flashing of the LED of the sensor 
eye is perceived. Then, press + to increase the security time and – to 
reduce it.

24 HOUR HYGIENE FLUSH: This model includes a 24 hours hygiene flush 
which is disabled. To activate the hygiene flush, press the clock button. Wait 
until a quick flashing of the LED in the sensor eye is perceived. Then press 
+ to activate the hygiene flush. To disable it again, press – to deactivate it.

COMFORT FLUSH: If your model includes a COMFORT FLUSH setting, it 
can be activated by pressing the flush button. 
When the button is pressed, one blink of the blue  in the sensor eye is per-
ceived. The pre-programmed flush cycle will take place then.
The Comfort flush cannot be interrupted or deactivated by pressing any 
button until it is over.

Summary of Contents for PETRA Q KSL00399

Page 1: ...1 OPERATION AND INSTALLATION GUIDE PETRA Q ELECTRONIC WALL MOUNTED FAUCET...

Page 2: ...is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non infringement Kassel Sanitar...

Page 3: ...ntents section Make sure all parts are accounted for before discarding any packaging material If any parts are missing do not attempt to install the electronic faucet until you obtain the missing part...

Page 4: ...NLET OUTLET STEP 1 INSTALLINGTHE FAUCET 5 Turn on the water supply Make sure there is no leakage 6 Assemble the mud guard cover to protect the solenoid valve Note the MIN and MAX marks on the box MIN...

Page 5: ...3 If your model is electricity powered detach the switching transformer from the faucet box switiching transformer 4 Detach the line cover in the box by unscrewing the line cover screw line cover INS...

Page 6: ...switching transformer connector PETRA Q 10 Assemble the panel to the cover seat and tighten it with the top screw 11 Make sure that the 6mm water outlet pipe is inserted into the faucet spout located...

Page 7: ...nce you have changed the detection range with the remote control this distance will be remembered by the sensor even if the power source is disconnected DELAY INTIME If required the delay in time can...

Page 8: ...h slowly 6 Keep your hand in front of the sensor until the slow flashing changes to quick flashing At this point move your hand to the required distance from the sensor and wait until the red light wi...

Page 9: ...eventing foreign particles to enter the lines If the water flow has decreased this can be because the filter is clogged The filter can be cleaned as follows 1 Shut off the water shut off valve angle v...

Page 10: ...ecautions and or installation recommendations outlined in this Installation Guide will void the warranty TROUBLESHOOTING SOLUTION CAUSE INDICATOR PROBLEM Replace battery Low battery 1 Sensor flashes c...

Page 11: ...22 Kassel Sanit r S L Avda de Castilla 1 Pol gono Industrial 28830 San Fernando de Henares Madrid Spain Daimlerstra e 2 D 93133 Burglengenfeld Germany Tel 34 916 778 993 Fax 34 916 777 774 info kassel...

Reviews: