DIFFUSER INSTALLATION

The effectiveness of the Robust-Aire™ system depends on the location of the diffusers in the pond. Place the 

Robust-Aire™ Diffusers equidistant from each other at a depth that is representative for most of the pond. 

Please contact Kasco with any questions about placement or system operation.

CAUTION: Do not use boats that tip easily for installation. 

Always wear a personal flotation device.

1. 

Kasco recommends marking the location of each diffuser at the surface with a buoy.

2. 

Unroll the SureSink™ Tubing on shore to remove any twists or knots. Performance will decrease if the 

tube is not properly uncoiled. 

3. 

Each tubing length is 100 feet. If more than one length of tubing is required to reach a diffuser location, 

connect any additional tubes according to the SureSink™ Tubing instructions. Unroll these tubes as you 

did the first tube. You can load multiple rolls of tubes into a boat and connect them as needed while 

making your way to the proposed diffuser location. You can also connect any number of 100’ lengths 

together and have someone assist in feeding it from shore. Cut off any excess tubing at the shore before 

connecting to the compressor.

4. 

Drop the loose end of the tubing near the compressor cabinet. Allow a few extra feet of tubing to work 

with so the tube will reach the cabinet after trenching between the shore and the compressor. 

5. 

Drive the boat in reverse to keep tubing clear of the propeller and slowly make your way to the marking 

buoy, placing the tubing as you go. 

6. 

Once you reach the marked buoy, thread a rope through the two holes of the diffuser base. Pull through 

until the midpoint of the rope is at the diffuser base. 

7. 

While holding the two ends of the rope, gently lower the diffuser assembly into the water.

8. 

Continue slowly lowering the assembly until it reaches the bottom of the pond. The diffuser will always 

land right side up.

9. 

The Robust-Aire™ Diffuser should now be seated properly on the bottom of the pond. You can remove 

the rope by pulling on one end. For ease of future maintenance, Kasco recommends leaving the rope 

looped through diffuser base and tying both ends to a marker buoy or duck decoy. This will allow you to 

easily locate diffusers and pull them to the surface  for maintenance.

10. 

Repeat the process for additional Robust-Aire™ Diffuser locations. 

Back to Contents

Summary of Contents for Robust-Aire RA10

Page 1: ...Rd Prescott WI 54021 715 262 4488 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 Installation Operation Manual Document number 774009 Document version 2022 1 0 LARGE CABINET DIFFUSED AERATION SYSTEM Robust Aire ...

Page 2: ... Safety First 2 Unit Specifications 2 Diffuser Installation 3 large cabinet installation 4 Remote Manifold Installation 5 Suggested Tools Supplies 5 Startup Procedure 7 Winter Operation 7 Filter Maintenance 8 General Maintenance 9 Troubleshooting 9 Warranty 10 Other Repairs 11 Repair Contact Form 12 ...

Page 3: ...tions including wearing a PFD Personal Flotation Device Consult a qualified electrician for electrical installation This system requires two receptacles SAFETY FIRST WARNINGS UNIT SPECIFICATIONS Electrical Shock Hazard Electrical Shock Hazard Model Compressor of Diffusers Voltage Phase Amps RA7 KM 120C 1 2HP x3 7 120V 1 10 5 RAH7 KM 120HC 1 2HP x3 7 208 240V 1 5 25 RA8 KM 120C 1 2HP x3 8 120V 1 10...

Page 4: ...meone assist in feeding it from shore Cut off any excess tubing at the shore before connecting to the compressor 4 Drop the loose end of the tubing near the compressor cabinet Allow a few extra feet of tubing to work with so the tube will reach the cabinet after trenching between the shore and the compressor 5 Drive the boat in reverse to keep tubing clear of the propeller and slowly make your way...

Page 5: ...RESOR CABINET 5052 Aluminum THIS DRAWING CONTAINS PROPRIETARY INFORMATION AND SHALL NOT BE USED REPRODUCED OR DISTRIBUTED WITHOUT THE PRIOR WRITTEN CONSENT OF KASCO MARINE INCORPORATED X 02 508 XX 010 254 XXX 005 127 ANGULAR 0 5 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES DIMENSIONS IN ARE MILLIMETERS TOLERANCES ON THIS DOCUMENT HAS BEEN ISSUED FOR ENGINEERING INFORMATIONAL PURPOSES ONLY A...

Page 6: ...inuously Lakes and ponds react differently to diffused aeration so exact time frames can be difficult to predict Sunny days are preferable to cloudy days for system start up since photosynthesis will supplement oxygen levels as the water is mixed If you have questions about this procedure please contact your distributor or e mail Kasco Customer Service at sales kascomarine com WINTER OPERATION The...

Page 7: ...top Failure to maintain clean air filter will lead to excessive heat and premature failure of the compressor Replacement air filter element part number 771018 Clean filter clear Dirty filter red Slidecabinetlidforward Liftlidwhennotchesareclear Front Reachundertheliponthefrontofthecabinetandpullthe outsideedgesofthetwotogglelatchesdowntoloosen Filter minders Toaccesstheintakefilters removethelidof...

Page 8: ... Ensure the fan is working properly Capacitor may need replacement Please contact Kasco or your distributor if any problems persist Use the maintenance sticker on the inside of the cabinet lid to track regular maintenance of your Robust Aire system The compressor motor cooling filter blue MUST be dry when re installing after cleaning In water bodies greater than 30 feet deep consider replacing pis...

Page 9: ...he warranty coverage has been established the unit may be sent to any Kas co Authorized Repair Center for evaluation and repair Please call Kasco at 715 262 4488 prior to shipping to receive any updated information and or Repair Form or call to locate your nearest Authorized Repair Center You can also email Kasco at sales kascomarine com Please include the repair form received from Kasco or your l...

Page 10: ... amount stated by the customer Example Please repair if total is under 150 00 before shipping charges All estimates that are rejected for repair will be destroyed unless otherwise directed by the customer If the customer would like the unit returned we will restore the unit as closely as possible to the condition in which we found it and ship at the customer s expense including shipping and handli...

Page 11: ...a chemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by this form and marked to Repairs attention Unit should be cleaned before shipping Kasco is NOT responsible for shipping damage accrued in return shipment It is the responsibility of the c...