Wire Sizing & Gland Sizing
The chart below shows the proper Gland to be used with different cord sizes. The measurements are based on the Outside Diameter
(O.D.) of the cord. Smooth, round cords should be used. (HAR H07RN-F)
Kasco Quick Disconnect 50 Hz Size Chart:
Gland
O.D. of Cord
Grey
7-9mm
White
9-11mm
Black
11-13mm
Yellow
13-15mm
Kasco 50 Hz Equipment Wire Size Chart
Model
Cord length
10m
30m
60m
90m
4400EJ
1.5mm2
1.5mm2
2.5mm2
4mm2
8400EJ
1.5mm2
2.5mm2
4mm2
6mm2
3.1EJ
1.5mm2
2.5mm2
6mm2
6mm2
2.3EJ
2.5mm2
2.5mm2
2.5mm2
4mm2
3.3EJ
2.5mm2
2.5mm2
4mm2
6mm2
5.3EJ
2.5mm2
4mm2
6mm2
6mm2
2.3EHJ
2.5mm2
2.5mm2
2.5mm2
2.5mm2
3.3EHJ
2.5mm2
2.5mm2
2.5mm2
2.5mm2
5.3EHJ
2.5mm2
2.5mm2
2.5mm2
2.5mm2