Kasco 2400EVFX Operation & Maintenance Manual Download Page 8

2400 - 4400 VFX FOUNTAIN MANUAL

7

TROUBLESHOOTING TIPS

ALWAYS DISCONNECT EQUIPMENT FROM ELECTRICAL SOURCE BEFORE SERVICING

SERVICE SHOULD ONLY BE PERFORMED BY A QUALIFIED TECHNICIAN OR ELECTRICIAN

Ground fault/earth leakage protection (RCD) tripping 

Typically indicates electrical current is leaking to earth (ground).

• 

Consult a qualified service technician or electrician to address the issue.

Possible causes: 

•  Control panel damaged or defective ground fault protection device (RCD, GFI)

•  Water contamination in the motor unit or Electrical motor damage

•  Power cord damage or water leak at quick disconnect

Collect this information for the electrician:

•  How long until the RCD trips after resetting? 

•  Does the trip time vary or repeat the same interval of time?

•  Does it trip randomly or same time of day?

•  How many times has it tripped?

•  Any electrical problems in the area recently, or changes made to site wiring?

Unit appears to run slowly

Typically indicates low voltage to the motor or motor damage.

• 

Contact a qualified service technician or electrician to measure for proper voltage and motor amps 

while the motor is operating.  Voltage drop should be no more the 5% from power source to motor 

control panel.

Unit hums and will not start

Typically indicates a motor capacitor problem (single phase motor), a motor controller problem (3 

phase), or debris preventing the unit from starting. 

• 

Turn the unit off and disconnect from power source to prevent motor damage. 

•  Remove the equipment from the water and inspect for debris or damage.

•  Remove the debris and clean the equipment.

• 

If there is no debris in the unit and it will not start. Turn the unit off and contact a qualified service 

technician to address the issue.  

Unit cycles on/off by itself

Typically indicates the motor is overheating. The Motor overload (single phase motor) will automatically 

reset once cooled down and restart the motor.
Possible causes:  

• 

Low water level, build-up of material on motor can preventing heat dissipation, or debris around the 

motor shaft or propeller area creating excess motor loading. 

• 

Turn the unit off and disconnect from power source to prevent motor damage.

•  Remove the equipment from the water and inspect for debris or damage.

•  If there is a build-up on the unit and motor can, remove the debris and clean the equipment.

Unit flow/performance fluctuates

Typically indicates debris is clogging the unit and preventing water flow into the unit.

• 

Turn the unit off and disconnect from power source.

•  Remove the equipment from the water and inspect for debris or damage.

•  If there is build-up on the unit and motor can, remove the debris and clean the unit.

Back to Contents

Summary of Contents for 2400EVFX

Page 1: ...L 1 MOVING WATER FORWARD SINCE 1968 Operation Maintenance Manual Document number 884158 Document version 2022 1 0 EVFX DECORATIVE AERATOR 2400EVFX 3400EVFX 4400EVFX 800 Deere Rd Prescott WI 54021 sale...

Page 2: ...Parts Included 3 Installation Instructions 5 Maintenance Recommendations 6 Troubleshooting Tips 7 Warranty 8 Other Repairs 9 Repair Contact Form 10 7 16 socket and ratchet 7 16 wrench 11 32 wrench for...

Page 3: ...codes Stay clear of all moving parts NEVER run the unit out of water This will damage the equipment and pose a danger to the operator Use extreme caution around water especially cold water NEVER lift...

Page 4: ...screw 4 251210 C 1 4 split washers 7 840537 D 1 4 3 4 OD Flat Washer 10 251300 E 1 4 20 x 1 3 4 Hex Head Bolt 3 475630 F Bottom Screen Section 3 361540 G 1 4 20 Nut 3 840536 H 8 nut 6 771034 I 8 flat...

Page 5: ...2400 4400 VFX FOUNTAIN MANUAL 4 ASSEMBLY INSTRUCTIONS B C D I J I H Align power cord with this notch G C D D E F 1 2 3 4 5 6 Back to Contents...

Page 6: ...ndary weight Normal water level Low water level High water level Alternate Installation Correct anchoring Incorrect anchoring Mooring lines are proper length and taut between unit and anchors at least...

Page 7: ...and clean the equipment regularly In all regions inspect and clean the equipment at least once a year It is easiest to clean the unit immediately after removing it from the water when the equipment is...

Page 8: ...not start Typically indicates a motor capacitor problem single phase motor a motor controller problem 3 phase or debris preventing the unit from starting Turn the unit off and disconnect from power so...

Page 9: ...arranty coverage has been established the unit may be sent to any Kasco authorized repair center for evaluation and repair Please call Kasco at 715 262 4488 prior to shipping to receive any updated in...

Page 10: ...irs after we have evaluated the unit but before we perform the work We will repair the unit only if repair costs are under a dollar amount stated by the customer Example Please repair if total is unde...

Page 11: ...is unit used in a chemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for...

Reviews: