1) Remove the packaging leaving the wash unit mounted on the pallet so that it is easier to transport. 

Remove the wash unit protections and any accessories contained in the packaging itself.

2) Position the wash unit and mark the fixing points (Fig. 2). Drill holes for the anchor bolts.

Fixing the wash unit

WARNING: Prepare the holes for the drain and electrical power supply, if applicable before fixing 

the wash units, either in side-by-side arrangement or with side drain. 

INSTALLATION

1) Undo the screws (1) fastening 

the rear casing. 

2) Undo the two screws fixing the 

wash unit to the pallet (2) and 

position the wash unit in the spot 

prepared for installation. 

Instructions for Installation, Use and Maintenance

Summary of Contents for DEVIL

Page 1: ...DEVIL WASH UNIT K7410_K7412_K7413 INSTRUCTIONS FOR INSTALLATION USE AND ROUTINE MAINTENANCE ...

Page 2: ...R SPECIFICATIONS 5 TRANSPORT AND STORAGE 6 DIMENSIONS 6 INSTALLATION SURFACE 7 PREPARATION 9 WASH UNIT ATTACHMENT 9 FLOOR DRAIN 10 WALL DRAIN 11 ELECTRICAL CONNECTION 12 TESTING 13 USE 13 SWITCHING ON THE EQUIPMENT 13 RELAX CONTROLS 14 JET MASSAGE CONTROLS 15 ROUTINE MAINTENANCE 16 CHAIR 16 WASHBASIN UNIT 16 CLEANING THE SURFACES 17 ELECTRICAL FUNCTIONS 18 IDENTIFICATION OF THE EQUIPMENT 18 INSTRU...

Page 3: ...f the wash unit It must be kept carefully throughout the dura tion of the wash unit and accompany the wash unit if it is transferred to a new user To avoid problems read this manual carefully before carrying out any operation on the wash unit and follow the instructions scrupulously The manufacturer accepts no liability for damage caused by negligence and or failure to observe the instructions in ...

Page 4: ...equirements indicated above the device was not installed following this manual the device is not used following this manual Instructions for Installation Use and Maintenance The wash unit chair is intended for professional use in hair treatment salons particularly in the hair washing area It cannot be used by more than one operator at the same time and can accommodate only one customer at a time T...

Page 5: ...sidues in the pipes It is recommended to install a pressure reducer in case of operating pressures above 5 bar It is also recommended to install a central filter for water with a high impurity content Technical specifications Test pressure 15 bar Cold water supply blue indicator pointing rightwards 1 2 pipe connection Hot water supply red indicator pointing leftwards 1 2 pipe connection Limits of ...

Page 6: ... stored in a dry indoor place stacking up to three packages on top of each other and without drastic temperature changes Environmental conditions for transport and storage Ambient temperature from 25 C to 50 C Relative humidity max 75 Environmental conditions of use Ambient temperature from 10 C to 40 C Relative humidity from 30 to 75 TRANSPORT AND STORAGE Instructions for Installation Use and Mai...

Page 7: ...installation 1 2 3 4 850 100 180 WARNING Open the side panel before fixing the wash unit in a side by side arrangement with a side drain INSTALLATION SURFACE Instructions for Installation Use and Maintenance Plant layout 1 Hot 3 8 1 2 thermostatic mixer 2 Cold 3 8 1 2 thermostatic mixer 3 ø 40 mm drain 4 Electrical cable outlet where required Cord 3X1 1500 mm 220 240 V 50 Hz 60 Hz Important note T...

Page 8: ...E 1 Determine the height of the wall drain from the ground 2 Open the rear wash unit casing 3 Locate the pre existing slot on the inside of the shoulder and drill a centring hole at the detected height 4 Fix the supplied flange with the appropriate screws on the outside of the shoulder 5 Open the side panel INSTRUCTIONS Dimensions in mm Instructions for Installation Use and Maintenance ...

Page 9: ...nts Fig 2 Drill holes for the anchor bolts Fixing the wash unit WARNING Prepare the holes for the drain and electrical power supply if applicable before fixing the wash units either in side by side arrangement or with side drain INSTALLATION 1 Undo the screws 1 fastening the rear casing 2 Undo the two screws fixing the wash unit to the pallet 2 and position the wash unit in the spot prepared for i...

Page 10: ...tic It is advisable to provide a gate valve upstream of each fitting Connections to the sewage system are established using a ø 40 drain pipe INSTALLATION Plant layout 1 Hot 3 8 2 Cold 3 8 3 ø 40 mm drain 4 Electrical cable outlet where required Cord 3X1 1500 mm 220 240 V 50 Hz 60 Hz 3 Place the two nylon discs supplied 1 under the base of the wash unit and fix it to the floor with the anchor bolt...

Page 11: ...nection may only be carried out by qualified technicians Open the side panel if the installation requires a power supply inlet from the wall or in a side by side arrangement 1 Opening the side panel 1 Determine the height of the wall drain from the ground 2 Open the rear wash unit casing 3 Locate the pre existing slot on the inside of the shoulder and drill a centring hole at the measured height 4...

Page 12: ...at the electrical system complies with Points 2 and 4 of the PREREQUISITES on page 4 It is advisable to provide an automatic switch and disconnector to cut off power to the wash units at any time 1 The wash unit models that require an electrical power supply are equipped with a 3x1 1 5 m long cord with a Schuko plug Plug it into the socket 2 By opening the junction box fig 1 of the wash unit it is...

Page 13: ...cold water mixer all open with the lever all to the left hot water mixer all open with the lever all to the right drain partially fill the basin remove the cap and drain repeat operation two or three times 1 After testing reposition the rear casing using the screws 1 Switching on the wash unit The wash unit is switched on by plugging it into the power supply USE Instructions for Installation Use a...

Page 14: ...or operating the electric footrest 1 This keypad can be used to activate the device for adjusting the wash unit footrest Foot pedal optional for operating the electric footrest 2 This foot pedal can be used to activate the device for adjusting the wash unit footrest RELAX CONTROLS Relax control panel D6510060 Relax control pedal D5710030 Optional Instructions for Installation Use and Maintenance ...

Page 15: ...ove the footrest down LED indicator for massage in operation Keypad for operating the jet massage 1 This keypad can be used to activate the device for adjusting the wash unit footrest and massage Foot pedal optional for operating the jet massage 2 This foot pedal can be used to activate the device for adjusting the wash unit footrest and massage JET MASSAGE CONTROLS Jet massage control panel C6420...

Page 16: ...ng parts every six months ROUTINE MAINTENANCE Washbasin unit Check every two months that there are no water leaks under the washbasin which could damage the base and the wash unit equipment To do this remove the casing of the wash unit by undoing the ap propriate screws 1 so that the part under the washbasin is visible Instructions for Installation Use and Maintenance ...

Page 17: ...e Cleaning the surfaces Disconnect power to the wash unit before cleaning or doing other jobs Do not use solvents to clean the metal parts Only use a damp cloth Use only sanitising liquid to clean plastic parts The upholstery of the chair must be cleaned with mild soap and water Do not use alcohol based products Never use aggressive or abrasive cleaning agents Please note that the chemicals contai...

Page 18: ...recycling plant By ensuring that this product is disposed of correctly you are helping to prevent poten tial negative consequences for health and the environment Please contact your local authority or waste collection service for more information on the treatment recovery and recycling of this product INSTRUCTIONS FOR DISPOSAL Electrical functions If the equipment does not work check that the powe...

Page 19: ...19 Instructions for Installation Use and Maintenance ...

Page 20: ...Via Masaccio 2 42124 Reggio Emilia Italy 39 0522 237010 Fax 39 0522 514669 e mail info karismabeauty com www karismabeauty com ...

Reviews: