11
2)
Opening the side panel
1 = Determine the height of the wall drain from the ground
2 = Open the rear wash unit casing.
3 = Locate the pre-existing slot on the inside of the shoulder and drill a centring hole at the detected
height.
4 = Fix the supplied flange with the appropriate screws on the outside of the shoulder.
5 = Open the side panel
Wall drain
WARNING:
The water connection may only be carried out by qualified technicians
Open the side panel if the installation requires a power supply inlet from the wall or in a side-by-side
arrangement.
1) Opening the side panel
1 = Determine the height of the wall drain from the ground
2 = Open the rear wash unit casing.
3 = Locate the pre-existing slot on the inside of the shoulder and drill a centring hole at the measured
height.
4 = Fix the supplied flange with the appropriate screws on the outside of the shoulder.
5 = Open the side panel.
INSTALLATION
Instructions for Installation, Use and Maintenance