background image

18

English

9.3.2 Visual inspection

Independent of the daily inspection, perform a visual in-

spection of all components of the spray unit before in-

stallation.

Do not use the product if deviations from its condition on 

delivery are determined. In this case, have a safety inspec-

tion to be conducted.

9.4

Service

9.4.1 Safety inspection

For safety reasons, safety inspection and service work 

may only be performed by service personnel from WOMA 

GmbH or by trained technical personnel (see chapter 2.4 

Personnel qualifications).

Have the product checked for the correct condition 

every 12 months.

9.4.2 Changing the cartridge

If additional water is expelled from the bypass line and/or 

the relief bores in the product when the spray unit is actu-

ated then the cartridge in the pressure housing must be re-

placed.

A pre-assembled cartridge (material number 9.919-046.0) 

may be replaced by untrained technical personnel as fol-

lows.

ATTENTION

Improper installation

Improper installation with damaged or dirty components 
can lead to malfunctions and damage to the product.
Perform a visual inspection of all spray device elements 
before installation.
All threads must be clean and undamaged.
The sealing surfaces of mating components must not have 
any scratches or scoring.
A non-pre-assembled cartridge may only be replaced by 
trained technical personnel.

(See illustration on page 2)

1. Release the bypass screw from the pressure housing 

and remove together with the cartridge.

2. Remove the spring from the pressure housing and re-

place with a new spring.

3. Disconnect the bypass screw from the cartridge.

4. Remove the seal (O-ring) from the groove in the bypass 

screw. 

5. Fit the seal (O-ring) in the groove.

6. Fit the bypass screw positively into the pre-assembled 

cartridge (material number 9.919-046.0).

7. Coat the thread of the bypass screw with thread instal-

lation paste before installation (see Chapter 12.2 Con-

sumables).

8. Coat the fitting surfaces of the cartridge with anti-seize 

installation (see Chapter 12.2 Consumables).

9. Screw the bypass screw with the cartridge into the pres-

sure housing and tighten to a torque of 100 Nm.

10

Troubleshooting guide

10.1 Safety instructions

For safety reasons, malfunctions may only be corrected by 

Service personnel from WOMA GmbH or by trained tech-

nical personnel.

11

Technical data

Subject to technical modifications.

12

Appendix

12.1 Water quality guideline

The limit values for the required water quality are an ex-

cerpt from the WOMA water quality guideline, which can 

be obtained from the WOMA GmbH (see Chapter 1.3 Ser-

vice).

12.2 Consumables

Material number

9.918-187.0

Operating pressure max.

bar

1500

Medium temperature max.

°C

95

Flow rate max.

l/min

45

Recoil force without body support

N

150

Recoil force with body support

N

250

Weight (without attachments) approx. kg

3.3

Length without spray lance approx.

mm

340

Height approx.

mm

200

Width approx.

mm

50

Connection for hose connection

M22x1.5-24°DKO

High-pressure hose connection

9/16"-18 UNF-LH

M24x1.5-24°DKO

Spray tube / spray lance connection 9/16"-18 UNF-LH
Bypass connection

G 3/8"

Controller

Mechanical by-

pass

Solid body content, max.

200 mg/l

Total water hardness

1 - 20 °H

CaO

10 - 200 mg/l

CaCO

3

18 - 357 mg/l

Calcium hardness

0.89 - 3.39 mmol/l

pH value

6.5 - 9.5

Base capacity (pH 8.2)

0 - 0.25 mmol/l

Proportion of total dissolved material 10 - 75 mg/l
Conductivity

100 - 1000 μS/cm

Chloride (e. g. NaCl)

< 100 mg/l

Iron (Fe)

< 0.2 mg/l

Fluoride (F)

< 0.15 mg/l

Free chlorine (Cl)

< 1 mg/l

Copper (Cu)

< 2 mg/l

Manganese (Mn)

< 0.05 mg/l

Phosphate (H

3

PO

4

)

< 50 mg/l

Silicate (Si

x

O

y

)

< 20 mg/l

Sulphate (SO

4

)

< 100 mg/l

Description

Container

Material 
number

Thread installation paste

500 g

9.892-362.0

Thread installation paste

207 g

9.740-194.0

Anti-seize installation paste

450 g

9.892-352.0

Anti-seize installation paste

85 g

9.740-195.0

Summary of Contents for WOMA HP-DG

Page 1: ...HP DG 9 920 778 0 English 2...

Page 2: ...17 16 15 10 13 1 2 3 4 5 6 7 8 9 12 14 18 19 20 18 21 22 11 A...

Page 3: ...stration conventions 1 5 1 Acton steps in the specified sequence Action steps to be executed are shown as a numbered or alphabetic list The sequence of the steps must be main tained Example 1 Action s...

Page 4: ...hazards that may occur and be capable of preventing these hazards through appropriate protective measures The operating personnel must be able to recognize any hazards in time and be able to implement...

Page 5: ...3 Intended use Check the product and work equipment prior to each use to make sure it is safe and working correctly see chapter 6 Startup Do not use a damaged spray device Never lock the trigger of t...

Page 6: ...tc vari ous surfaces and materials such as steel concrete etc This can be achieved using various different water tools from WOMA GmbH This product is only to be used with water conforming to the WOMA...

Page 7: ...e high pressure water jet machine to the se cured spray device using a suitable high pressure hose 6 Startup 6 1 Safety instructions DANGER Risk of injury from the high pressure water jet Contact with...

Page 8: ...ith hot water Allow the product to cool down after hot water operation or flush the spray device using cold water operation 7 2 Shutting down the product Note Depressurised jet liquid flows out of the...

Page 9: ...oat the thread of the bypass screw with thread instal lation paste before installation see Chapter 12 2 Con sumables 8 Coat the fitting surfaces of the cartridge with anti seize installation see Chapt...

Page 10: ...length 9 918 623 0 3 Handle 6 025 300 0 4 Spray lance 1500 bar 300 7000 mm in length See WOMA product range Spray lance 3000 bar 300 6000 mm in length See WOMA product range 5 Splash guard 9 871 040 0...

Reviews: