background image

16

English

ATTENTION

Improper installation

Improper installation with damaged or dirty components 
can lead to malfunctions and damage to the product.
Perform a visual inspection of all product elements before 
installation.
All threads must be clean and undamaged.
The sealing surfaces of mating components must not have 
any scratches or scoring.

5.2

Installing the spray tube/spray lance

1. Release the pressure screw from the pressure housing 

and remove together with the pressure ring (see illustra-

tion on page 2).

2. Push the pressure screw onto the spray tube/spray 

lance.

3. Coat all threads with installation paste before installation 

(see Chapter 12.2 Consumables).

4. Unscrew the pressure ring (left-hand thread) until 1-2 

threads are visible.

5. Push the spray tube/spray lance with the pressure 

screw into the pressure housing.

6. Screw the pressure screw into the pressure housing (30 

mm) and tighten to a torque of 160 Nm.

7. When cleaning surfaces (e.g.cleaning concrete), install 

the splash guard (see Chapter 13 Accessories) on the 

spray tube/spray lance.

8. Screw the nozzle holder or other water tool onto the 

spray tube/spray lance and tighten to a torque of 

100 Nm unless specified otherwise.

Major characteristics of the water tools

Water tools (e.g. nozzles, turbo nozzle, Orbimaster, 

Speedy) used on manually operated spray devices from 

WOMA GmbH may have multiple nozzle outlet open-

ings. These may be spotlight nozzles or flat jet nozzles. 

Motor-driven rotation, or self-driven rotation through an-

gled nozzles is possible (see the WOMA product 

range).

Water tools extend the range of possible uses for the 

spray device. Further information is available from your 

WOMA sales partner.

5.3

Installing the bypass line

1. Coat all threads with installation paste before installation 

(see Chapter 12.2 Consumables).

2. Screw the bypass pipe or bypass hose connection into 

the pressure housing (32 mm) and tighten onto the by-

pass connection to a torque of 100 Nm (see illustration 

on page 2).

5.4

Installing the hose connection

(see illustration on page 2)

Note

Take care to ensure that only hoses approved for the max-
imum operating pressure are used.

1. Coat all threads with installation paste before installation 

(see Chapter 12.2 Consumables).

2. Screw the adapter (material number 9.918-624.0) into 

the pressure housing and tighten to a torque of 130 Nm.

3. Fit the seal (O-ring) in the adapter.

4. Screw the hose connection into the adapter and tighten 

to a torque of 130 Nm.

5. Connect the high-pressure water jet machine to the se-

cured spray device using a suitable high-pressure hose.

6

Startup

6.1

Safety instructions

DANGER

Risk of injury from the high-pressure water jet

Contact with high-pressure water jets can cause irreversi-
ble injuries or even death.
Do not direct high-pressure water jets towards humans, 
animals or electrical equipment.
Ensure that the product is correctly installed before use 
(see chapter 5 Installation)
.
Due to the potential hazards (e.g. recoil, cutting effects of 
the water jet etc.) be sure to use the product only in the in-
tended manner (see chapter 3 Intended use)
.
The product may only be operated by personnel who have 
been trained for this and who have been instructed in the 
potential hazards (see chapter 2.4 Personnel qualifica-
tions).
Wear the prescribed personal protective equipment when 
spraying (see chapter 2.8 Protective gear
).

Note

Do not operate the product at temperatures below 0 °C.

6.2

Before switching on the high pressure 

water jet machine

The product is correctly installed and connected to the 

high-pressure water jet machine. The high pressure water 

jet machine is not switched on.

Perform the following steps each time before switching on 

the high water pressure, i.e. when the high pressure pump 

is stationary and pressurised:

1. Vent the entire high pressure water jet machine using 

the filter and the vent hose on the high pressure pump.

2. Rinse the high pressure water jet machine, including the 

high pressure hose, with fresh water while the product 

is depressurised.

3. Check the bypass line on the water outlet. 

Water must be expelled from the bypass line when the 

product is not actuated.

4. Check that the trigger and the trigger catch are function-

ing smoothly and freely.

The trigger must return automatically to its original posi-

tion after actuation and engage into the trigger. It should 

only be possible to actuate the trigger when the trigger 

catch is actuated once again.

5. Check the product condition for differences from its con-

dition on delivery.

Has the position of the pressure point changed, for ex-

ample? When switching from 

Trigger actuated

 to 

Trigger 

not actuated

, the water volume flow in the bypass line 

must be expelled immediately.

Note

Do not use the product if the checks are unsuccessful. In 
this case, have a safety inspection conducted (see chapter 
9.4 Service
).

6.3

Before starting spraying

The product is correctly installed and connected to the 

high-pressure water jet machine. 

The high-pressure water jet machine is switched on.

Note

Depressurised jet liquid flows out of the bypass line when 
the high-pressure water jet machine is switched on and the 
product is not actuated.

Summary of Contents for WOMA HP-DG

Page 1: ...HP DG 9 920 778 0 English 2...

Page 2: ...17 16 15 10 13 1 2 3 4 5 6 7 8 9 12 14 18 19 20 18 21 22 11 A...

Page 3: ...stration conventions 1 5 1 Acton steps in the specified sequence Action steps to be executed are shown as a numbered or alphabetic list The sequence of the steps must be main tained Example 1 Action s...

Page 4: ...hazards that may occur and be capable of preventing these hazards through appropriate protective measures The operating personnel must be able to recognize any hazards in time and be able to implement...

Page 5: ...3 Intended use Check the product and work equipment prior to each use to make sure it is safe and working correctly see chapter 6 Startup Do not use a damaged spray device Never lock the trigger of t...

Page 6: ...tc vari ous surfaces and materials such as steel concrete etc This can be achieved using various different water tools from WOMA GmbH This product is only to be used with water conforming to the WOMA...

Page 7: ...e high pressure water jet machine to the se cured spray device using a suitable high pressure hose 6 Startup 6 1 Safety instructions DANGER Risk of injury from the high pressure water jet Contact with...

Page 8: ...ith hot water Allow the product to cool down after hot water operation or flush the spray device using cold water operation 7 2 Shutting down the product Note Depressurised jet liquid flows out of the...

Page 9: ...oat the thread of the bypass screw with thread instal lation paste before installation see Chapter 12 2 Con sumables 8 Coat the fitting surfaces of the cartridge with anti seize installation see Chapt...

Page 10: ...length 9 918 623 0 3 Handle 6 025 300 0 4 Spray lance 1500 bar 300 7000 mm in length See WOMA product range Spray lance 3000 bar 300 6000 mm in length See WOMA product range 5 Splash guard 9 871 040 0...

Reviews: