37
Maintenance
Charging
Before operating the charger make sure to read and
understand the instructions that come with the charger.
Never attempt to charge a battery without first
reviewing and understanding the instructions for the
charger being used
Always make sure the chargers charging curve
meets the battery’s charging requirement; never
charge a visibly damaged battery; never charge a
frozen battery.
Toujours s'assurer que les chargeurs de courbe
respectent l'exigence de charge de la batterie.
ne jamais charger une batterie visiblement
endommagée; ne jamais charger une batterie
gelée.
1.
Connect the charger leads to the battery.
2.
Make sure that the charger lead, both at the
charger and the battery side, connections are tight.
3.
Turn the charger on.
4.
Turn the battery on (if required).
NOT ALL CHARGERS ARE CAPABLE OF
CHARGING LITHIUM BATTERIES!
During system design CONFIRM that your chosen
charger is not capable of transient spikes that
exceed the published MAXIMUM TERMINAL
RATINGS of the battery
TOUS LES CHARGEURS NE SONT PAS APTES À
CHARGER DES BATTERIES AU LITHIUM.
Durant la conception du système, CONFIRMER que
le chargeur que vous avez choisi n'est pas capable
d'une hausse de tension dépassant les COTES DE
BORNE MAXIMALES de la batterie.
Discharging
•
Turn on battery.
•
Turn on load
NOTE: Do not discharge battery below
recommended minimum operating voltages.
NOTE: Do not discharge battery at rates greater than
recommended operating currents.
Storage
Systems should be stored out of direct sunlight under
the following temperature conditions:
System should be put into storage at 80% SOC and
checked monthly to ensure the system SOC (state of
charge) does not fall below 20%/ At 2-% SOC the
battery will self discharge in approximately 2 months.
Protection & Faults
• BMS (battery management system) generates faults
when maximum operating limits are reached.
• BMS sounds a buzzer when fault limits are triggered.
• BMS monitors the following information for faults and
warning:
•
Cell module voltage
•
Battery current
•
Battery temperature
Faults & Corrective Actions
In the event of a fault the BMS (battery management
system) will sound an audible buzzer warning and the
system will shut off after a 120 second delay.
Minimum Storage Temperature
-20°C / -4°F
Maximum Storage Temperature
45°C / 113°F
FAULT LEVELS
Parameter
Trigger Point
High Temperature
60°C / 140°F
High Voltage
3.7 V in any cell module
Low Voltage
2.5 V in any cell module
Over Current
150 A
86398200 Operator Manual - Chariot 3 - iextract 26 Duo
Summary of Contents for Windsor Chariot 3 iExtract 26 Duo
Page 26: ...26 Notes 86398200 Operator Manual Chariot 3 iExtract 26 Duo...
Page 59: ...59 86398200 Operator Manual Chariot 3 iExtract 26 Duo...
Page 63: ...1 BRUSH DECK 1 Valid on 06 03 2019 Page 3 69...
Page 65: ...2 BRUSH DECK 2 Valid on 06 03 2019 Page 5 69...
Page 67: ...3 BRUSH DECK LIFT Valid on 06 03 2019 Page 7 69...
Page 69: ...4 BRUSH DECK MOUNTING Valid on 06 03 2019 Page 9 69...
Page 71: ...5 BRUSH DECK DRIVE Valid on 06 03 2019 Page 11 69...
Page 73: ...6 GRP BUMPER BLK CS26 Valid on 06 03 2019 Page 13 69...
Page 75: ...7 CONSOLE Valid on 06 03 2019 Page 15 69...
Page 77: ...8 Console Mounting Valid on 06 03 2019 Page 17 69...
Page 79: ...9 CONTROL PANEL UPPER Valid on 06 03 2019 Page 19 69...
Page 81: ...10 CONTROL PANEL LOWER Valid on 06 03 2019 Page 21 69...
Page 83: ...11 Control Panel Mounting Valid on 06 03 2019 Page 23 69...
Page 85: ...12 CONTROLLER Valid on 06 03 2019 Page 25 69...
Page 87: ...13 DECALS 0 250 116 0 Valid on 06 03 2019 Page 27 69...
Page 89: ...14 DRIVE MOUNTING Valid on 06 03 2019 Page 29 69...
Page 91: ...15 Frame Valid on 06 03 2019 Page 31 69...
Page 93: ...16 Platform Valid on 06 03 2019 Page 33 69...
Page 95: ...17 Platform Footbox Rear Wheels Valid on 06 03 2019 Page 35 69...
Page 97: ...18 Rear Cover Valid on 06 03 2019 Page 37 69...
Page 99: ...19 RECOVERY Valid on 06 03 2019 Page 39 69...
Page 101: ...20 SOLUTION SYSTEM Valid on 06 03 2019 Page 41 69...
Page 103: ...21 STEERING Valid on 06 03 2019 Page 43 69...
Page 105: ...22 Tank Valid on 06 03 2019 Page 45 69...
Page 107: ...23 VACUUM SHOE LIFT Valid on 06 03 2019 Page 47 69...
Page 108: ...23 VACUUM SHOE LIFT Valid on 06 03 2019 Page 48 69...
Page 110: ...24 VACUUM SHOE MOUNTING Valid on 06 03 2019 Page 50 69...
Page 112: ...25 VACUUM SHOE Valid on 06 03 2019 Page 52 69...
Page 114: ...26 VACUUM Valid on 06 03 2019 Page 54 69...
Page 116: ...27 WIRING BATTERIES 0 250 135 0 Valid on 06 03 2019 Page 56 69...
Page 119: ...28 WIRING COMPONENTS Valid on 06 03 2019 Page 59 69...
Page 121: ...29 Battery Exchange 1 Valid on 06 03 2019 Page 61 69...
Page 123: ...30 Battery Exchange 2 Valid on 06 03 2019 Page 63 69...
Page 125: ...31 Battery Exchange 3 Valid on 06 03 2019 Page 65 69...
Page 127: ...32 PUMP OFF AISLE Valid on 06 03 2019 Page 67 69...