MALFUNCTIONS AND MAINTENANCE
- 77 -
4
Malfunctions and Maintenance
4.1
Malfunction, Causes and Corrective Measures
If an electrical consumer fails to function, the corresponding fuse in
the switch cabinet and E-distributor should always be checked first.
If the fuse cuts out again after resetting it, the operation is to be halted
and an electrician consulted.
4.1.1
Displays on the Switch Cabinet
Fig. 51
1
2
3
4
5
Fault
Cause
Remedy
Rotating field display (51/1) on
the electrical connection panel
illuminates, red
Reverse phase rotation direction
A qualified electrician must
reverse the direction of phase
rotation by changing the
phases in the system plug
(Use phase inverter in the plug)
One or several phase control
lamps (51/5) fails to illuminate
Bulb of the lamp defective
Replace electric bulb
Interference in the 400 V supply
For external supply:
Check plug and cable
For electric generator unit
operation:
Check generator
"Fault reset" button (51/2) illu-
minates
Fault as indicated on the operat-
ing panel
Remedy fault and press "Fault
reset" button