background image

15

Maintenance

Troubleshooting

Service Schedule

PROBLEM.

CAUSE

SOLUTION

No power, vacuum 
motor will not run

Is the cord plugged in?

Plug in cord.

Circuit breaker tripped in building.

Reset breaker.

Thermal protector tripped

Motor will restart after cooling down.  To 
prevent repeated tripping, clear all restric-
tions out of hose and tools, replace paper 
filter bag.  Clean cloth filter bag and 
internal pleated filter, clear all restrictions to 
the exhaust air flow.

Faulty switch.

Call for service.

Faulty power cord.

Call for service.

Poor vacuum 
performance

Debris plugging hose, wand or accessory 
tool.

Remove debris.

Paper bag full.

Replace bag.

Cloth bag plugged.

Remove from machine, turn inside out and 
shake or brush clean.

Hosecuffs loose or hose cracked.

Tighten cuffs or replace hose.

Cap loose on top of machine.

Tighten cap.

MAINTENANCE

DAILY

WEEKLY

MONTHLY QUARTERLY

BI-

ANNUALLY

Check bag and replace if necessary

*

Check hoses for wear, blockages, or 
damage

*

Check major gaskets for leakage

*

Check brush-should be clean with no 
lint or strings attached

*

Wind cord and store in upright position *
Check hoses for cracks or holes

*

Check all cords and handles for 
damage or cracks; replace as 
necessary

*

Inspect and replace all filters including 
exhaust, intake, and microfilters

*

Check all gaskets for wear and 
leakage

*

Check vac motor carbon brushes

*

Check for arcing and pitting on any 
electrical contacts; replace if found

*

Inspect and clean vac shoe; check for 
dents and damage which would detri-
mentally effect vacuum and brush 
movement

*

Check overall performance of machine

*

Replace pleated dome filter

*

86394670 - VacPac

Summary of Contents for VP6

Page 1: ...Read these instructions before using the machine 86394670 A 12 01 14 Operating instructions ENG MODELS VP6 10140130 UVP6 98413240 VP10 10140140 UVP10 98413250...

Page 2: ...2 Machine Data Label 86394670 VacPac...

Page 3: ...y Level 7 Grounding Instructions 9 Safety Label Location 10 Operations Technical Specifications 12 Equipment Set Up 13 Machine Operation 13 Maintenance Daily Maintenance 14 Troubleshooting 15 Service...

Page 4: ...n The PARTS LIST section contains assembled parts illustrations and corresponding parts list The parts lists include a number of columns of information REF column refers to the reference number on the...

Page 5: ...sharp edges or corners Keep cord away from heated surfaces Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not put any object into openings Do not use with any opening blocke...

Page 6: ...u des coins Garder le cordon l cart des surfaces chaudes Ne pas d brancher en tirant sur le cordon Tirer plut t la fiche Ne mettez aucun objet dans les ouvertures Ne l utilisez pas avec une ouverture...

Page 7: ...n of equipment Report machine damage or faulty operation immediately Do not use the machine if it is not in proper operating condi tion Following is information that signals some potentially dangerous...

Page 8: ...t d une d faillance ou d une d t rioration de la machine Ne pas utiliser la machine si celle ci ne fonctionne pas correctement Lire soigneusement les informations ci dessous signalant certains dangers...

Page 9: ...to connect this plug to a 2 pole receptacle as shown in Fig B if a properly grounded outlet is not available The temporary adaptor should be used only until a properly grounded outlet Fig A can be in...

Page 10: ...Safety Safety Label Location NOTE This drawing indicates the location of safety label on the machine If at any time the label becomes illegible promptly replace it WARNING LABEL 86198960 86394670 VacP...

Page 11: ...11 NOTES 86394670 VacPac...

Page 12: ...2 2 Cubic Meter Min Waterlift 95 Inches of Water Filter Bag VP6 UVP6 6 Quart VP10 UVP10 10 Quart General Dimensions Weight Vacuum Hose 5 1 5m X 1 5 3 8cm Diameter Weight VP6 UVP6 10 1 Lb 4 6 Kg VP10 U...

Page 13: ...st and tighten till comfortable 6 Plug in power cord from machine into properly grounded wall outlet see grounding instructions Machine Operation The unit is a commercial vacuum designed for dry pick...

Page 14: ...without harming filtering capacity Allow to dry completely before using 2 Wipe down exterior of machine 3 Check round pleated filter at bottom of vac chamber and clean if necessary For best results re...

Page 15: ...r brush clean Hosecuffs loose or hose cracked Tighten cuffs or replace hose Cap loose on top of machine Tighten cap MAINTENANCE DAILY WEEKLY MONTHLY QUARTERLY BI ANNUALLY Check bag and replace if nece...

Page 16: ...16 Notes 86394670 VacPac...

Page 17: ...17 86394670 VacPac Parts PARTS...

Page 18: ...18 VacPac 25 5B 1 7 8 4B 23 9 15 15 21 2 19 14 24 10 11 11A 12 20 3 13 12A 17 4A 5A 16 18 22 6 21A 26 86394670 VacPac...

Page 19: ...99050 1 RING MTR COMP W SCREWS 11A 86199070 1 SCR MTR COMP RING 4 PKG 12 86198790 1 DIFFUSER AIR W SCREWS 12A 86199080 1 SCR AIR DIFFUSER 2 PKG 13 86198890 1 FILTER AIR SOUND DIFFUSER 14 86198950 1 KI...

Page 20: ...20 Wiring Diagram 86394670 VacPac 1 SEE VACPAC BOM FOR ALL OTHER PART NUMBERS POWER CORD VAC MOTOR DISCONNECT QUICK CORD SWITCH...

Page 21: ...21 86394670 VacPac Wiring Diagram REF PART NO QTY DESCRIPTION SERIAL NO NOTES 1 86218010 1 FUSE ASM VP6 10...

Page 22: ...22 Notes 86394670 VacPac...

Page 23: ...23 OPTIONS Options...

Page 24: ...24 Accessory Tools and Kits 1 2 3 4 3 5 6 7 8 9 10 11 14 13 12 15 16 86394670 VacPac...

Page 25: ...LITE 5 86033020 1 TOOL QUICK SWEEP 6 86286660 1 WAND DOUBLE CURVE 2 PC ALUM INCL 7 8 7 86199060 1 RING BOTTOM WAND 8 86199030 1 NUT BOTTOM WAND 9 86000090 1 TUBE 20 EXTENSION 10 86198760 1 TOOL 16 CR...

Page 26: ...H BAG FOR VP10 ONLY 86198900 FILTER BAG LINER CLOTH VP6 86198850 FILTER BAG VP10 PAPER PKG 10 86198910 FILTER BAG VP6 PAPER PKG 10 86392850 FILTER DOME VAC MOTOR HEPA 86198890 FILTER AIR SOUND DIFFUSE...

Page 27: ...27 Serial Numbers REF NO MODEL SERIAL 1 86394670 VacPac...

Reviews: