background image

English

7

Manual mode  

Note

In manual mode, the pump stays switched on. The fluid 
level must be at least 60 mm (SP 16000 Dirt) or 50 mm 
(SP 22000 Dirt) for the pump to prime itself in manual 
mode. The pump can pump up to a residual fluid height 
of 25 mm (SP 16000 Dirt) or 35 mm (SP 22000 Dirt). 
The specified residual fluid height is only achieved in 
manual mode.
The float switch must be able to move freely.

1. Fasten the float switch in the lock pointing upwards.

Illustration H

ATTENTION

Risk of damage from dry running!

Dry running leads to increased wear on the pump.
Do not leave the pump unattended in manual operation.
In case of dry running, immediately pull the mains plug 
out of the socket.

2. Plug the mains plug into a mains socket.

Finishing operation

1. Pull the mains plug out of the socket.

The device stops.

ATTENTION

Risk of damage!

Risk of damage due to dried soiling or additives.
Rinse and clean the device immediately after each use.

2. If dirty liquids or liquids with additives have been 

pumped, rinse and clean the device immediately af-
ter finishing operation, see chapter 

 Rinsing and 

cleaning

.

3. Drain the device and accessories and let them dry.

Care and maintenance

DANGER

Risk of electric shock and risk of injury!

The device contains electrical and mechanical compo-
nents.
Cleaning and user maintenance may not be carried out 
by children.

Rinsing and cleaning

ATTENTION

Risk of damage!

Risk of damage due to dried soiling or additives.
Rinse and clean the device immediately after each use.

1 If dirty liquids or liquids with additives have been 

pumped, the device must be rinsed afterwards: Use 
the device to pump clear fresh water without addi-
tives until all soiling or additives have been flushed 
out of the device.

DANGER

Risk of electric shock and risk of injury!

The device contains electrical and mechanical compo-
nents.

Always disconnect the device from the power supply 
before assembling, disassembling or cleaning.

2 Pull the mains plug out of the socket.
3 Press the Quick-Connect button and remove the 

connection nozzle.

Illustration C

4 Where necessary, remove residue from the hose 

and on Quick-Connect.

5 Clean the outside of the device with a soft, clean 

cloth and clear fresh water.

6 Drain the device and accessories and let them dry.

Service

The device is maintenance-free.

Transport

Manual transport

CAUTION

Risk of injury from tripping!

There is a risk of injury from tripping on loose cables and 
hoses.
Be careful of cables and hoses when moving the device.

1. Lift and carry the device by the carrying handle.

Transport in vehicles

WARNING

Risk of injury, risk of damage! 

Note the weight of the device during transport.
Store or secure the device in accordance with applica-
ble guidelines so that it cannot slip or be thrown around 
during transport.

2. When transporting the device in vehicles, secure it 

to prevent it from slipping or overturning in accord-
ance with the respectively applicable guidelines.

Storage

ATTENTION

Risk of damage due to frost!

An incompletely emptied device can be damaged by 
frost.
Completely empty the device and accessories before 
storing them.
Protect the device from frost.
Store the device in a frost-free place and not outdoors.

CAUTION

Risk of injury and damage!

The device may tip over on sloping surfaces.
Be aware of the weight of the device during storage.

1. Completely empty the pump and accessories.
2. Allow the pump and accessories to dry out.
3. Store the pump in a frost-protected place.

Troubleshooting guide

Malfunctions often have simple causes that you can 
remedy yourself using the following overview. When in 
doubt, or in the case of malfunctions not mentioned 
here, please contact your authorised Customer Service.

Fault

Cause

Rectification

The pump is running, but 
not delivering

Air is in the pump.

1. Pull the mains plug out of the socket and 

plug it in again several times, until the fluid 
is drawn in.

The suction area is clogged.

1. Pull the mains plug out of the socket.
2. Clean the suction area.

The fluid level is too low in manual oper-
ation.

1. Immerse the pump deeper into the feed flu-

id if possible, see chapter 

 Operation

.

Summary of Contents for SP 16.000 Dirt

Page 1: ...SP 16 000 Dirt SP 22 000 Dirt 5 991 079 0 09 22 English 4 10...

Page 2: ...A...

Page 3: ...B C D E F G H...

Page 4: ...pproved according to the Austrian Electro technical Association standard VE B EN 60555 Parts 1 to 3 where the nominal secondary output volt age of the transformer must not exceed 230 V Only operate th...

Page 5: ...onmental protection The packing materials can be recycled Please dispose of packaging in accordance with the en vironmental regulations Electrical and electronic appliances contain valu able recyclabl...

Page 6: ...d ground in the pumped liquid or immerse it via a rope attached to the carrying handle Note The suction area must not be blocked by soiling If the ground is muddy place the pump on a brick or similar...

Page 7: ...ins plug out of the socket 3 Press the Quick Connect button and remove the connection nozzle Illustration C 4 Where necessary remove residue from the hose and on Quick Connect 5 Clean the outside of t...

Page 8: ...down 3 Remove any dirt particles in the suction ar ea 4 Clean the suction area 5 Prevent the pump from running dry Dirt particles block the suction area 1 Pull the mains plug out of the socket 2 Clea...

Page 9: ...well as in the version put into circulation by us This declaration shall cease to be valid if the product is modified without our prior approval Product Pump Type 1 645 xxx Currently applicable UK Re...

Page 10: ...14 SP 16 000 Dirt SP 22 000 Dirt V 230 240 230 240 Hz 50 50 W 550 750 l h 16 000 22 000 MPa bar 0 08 0 8 0 08 0 8 m 8 8 m 7 7 5 35 5 35 mm 20 30 mm 60 50 mm 25 35 kg 4 9 6 5...

Page 11: ...13 1 2 3 C 4 5 6 1 2 1 2 3 1 1 2 1 1 1 2 3 4 5 1 2 1 2 1 2 1 2 3...

Page 12: ...G 1 5 C 1 D 2 1 E 1 F 2 5 G 2 2 5 60 SP 16 000 Dirt 50 SP 22 000 Dirt 25 SP 16 000 Dirt 35 SP 22 000 Dirt 1 H 2 1 2 3 SP 16 000 Dirt SP 22 000 Dirt 18 21 20 24 4 12 6 15 SP 16 000 Dirt SP 22 000 Dirt...

Page 13: ...kaercher com REACH www kaercher com A 1 2 3 4 5 G1 1 1 1 G1 6 G1 7 8 9 10 G 1 1 G 1 11 12 SP 16 000 Dirt G1 13 SP 22 000 Dirt 1 SP 16 000 Dirt SP 22 000 Dirt G1 G 1 1 1 1 G1 G 1 1 1 1 G 1 1 B 2 3 G1...

Page 14: ...10 30 1 3 VE B EN 60555 VE 230 30 60 10 10 11 11 11 11 11 11 12 12 13 13 13 14...

Page 15: ......

Page 16: ...e uns Ihre Meinung Rate your product and tell us your opinion valuer votre produit et dites nous votre opinion Rese e su producto y d ganos su opini n www kaercher com welcome www kaercher com dealers...

Reviews: