background image

– 11

Illustration 

Insert steering roller and running wheels and lock 
them.

Illustration 

Connect the required accessories (see Chapter 
"How to use the accessories“) to the steam gun. In-
sert the open end of the accessory on the steam 
gun and push onto the steam gun until the unlock-
ing button of the steam gun locks into place.

Illustration 

Use the extension tubes if necessary. To do so, 
connect one or both extension tubes to the steam 
gun. Insert the required accessories on the free 
end of the extension tube.

Move the selector switch for the steam volume
back (steam lever locked).

Illustration 

To detach the accessory parts, press the unlocking 
button and pull the items apart.

Note: 

If you always use usual commercial distilled water it is 
not necessary to descale the boiler.

ATTENTION

Do not use condensation water from the drier! 
Do not fill in detergents or other additives!

Remove the safety lock from the device.

Illustration 

Completely empty the water tank to remove exist-
ing water.

Fill the boiler with a maximum of 1 liters of fresh tap
water.

Note: 

You can cut down the heating-up time by using 
warm water.

Screw the safety cap back onto the device. 

Place the unit securely on a firm surface.

Insert the mains plug into a socket.

Press the ON switch to turn on the appliance.
Both indicator lamps must illuminate.

The orange indicator lamp goes out after approxi-
mately 8 minutes. 
The steam cleaner is ready to use.

Use the selector switch for the steam volume to regulate 
the discharged steam. The selector switch has three po-
sitions: 

Set selector switch to the required steam volume.

While operating the steam switch, always direct the 
steam gun at a separate piece of cloth until the 
steam is emitted evenly.

Note:

 The heating of the steam cleaner is turned on in 
regular intervals during the operation of the appli-
ance in order to maintain the pressure in the boiler 
at a constant level. When the heating is turned on, 
the orange indicator lamp (heater) lights up.

Water needs to be filled into the boiler, if the steam vol-
ume decreases during work and no more steam is emit-
ted in the end.

Note: 

The safety lock cannot be opened as long as slight pres-
sure remains in the boiler.

Illustration 

Press the OFF switch to turn off the appliance.

Illustration 

Push the steam switch until steam discharge stops. 
Now, the boiler of the appliance is unpressurized.

Move the child protection unit toward the back 
(steam lever locked).

Remove the safety lock from the device.

Fill the boiler with a maximum of 1 liters of fresh tap 
water.

Screw the safety cap back onto the device. 

Press the ON switch to turn on the appliance.

The orange indicator lamp goes out after approxi-
mately 8 minutes. 
The steam cleaner is ready to use.

Illustration 

Press the OFF switch to turn off the appliance.

Disconnect the mains plug from the socket.

Illustration 

Push the steam switch until steam discharge stops. 
Now, the boiler of the appliance is unpressurized.

Move the child protection unit toward the back 
(steam lever locked).

Operation

Attaching the Accessories

Removing the Accessories

Fill up with water

Turning on the Appliance

Adjusting the Steam Quantity

Maximum steam volume

Reduced steam volume

No steam - child protection

Note: 

In this lever position, the steam lever cannot be 
used.

Refilling Water

Turning Off the Appliance

Summary of Contents for SC EasyFix ATK 2

Page 1: ...SC EasyFix ATK 2 Operating Instructions Please read the operating instructions carefully before using the unit 59690370 07 19 ...

Page 2: ...G 1 2 1 2 1 2 G L M J K 2 ...

Page 3: ...O N 3 ...

Page 4: ...re parts please visit www kaercher com The warranty terms published by the relevant sales company are applicable in each country We will repair potential failures of your appliance within the warranty period free of charge provided that such failure is caused by faulty material or defects in manufacturing In the event of a warranty claim please contact your dealer or the nearest authorized Custome...

Page 5: ... to cool down before performing any maintenance work Repair works may only be performed by the authorized customer service The connection between the power cord and extension ca ble must not lie in water 몇 WARNING The appliance may only be connected to an electric sup ply that has been installed by an electrician in accordance with IEC 60364 The appliance may only be connected to alternating cur r...

Page 6: ...must not be operated by children or per sons who have not been in structed accordingly This appliance is not intended for use by persons with limit ed physical sensory or men tal capacities or lacking expe rience and or skills unless such persons are accompa nied and supervised by a per son in charge of their safety or they have received precise instructions on the use of this appliance and have u...

Page 7: ...pe 몇 CAUTION CAUTION Please read the operating in structions 몇 CAUTION Safety devices protect the user and must not be modi fied or bypassed The pressure controller keeps the boiler pressure dur ing the operation as constant as possible The heating is turned off if the maximum operating pressure of 4 bar is reached in the boiler and is reactivated in case of a pressure drop in the boiler due to st...

Page 8: ...NGE A5 Safety cap A6 Holder for accessories A7 Storage holder for floor nozzle A8 Carrying handle A9 Accessories storage A10 Mains cable with mains plug A11 Running wheels 2 ea A12 Steering roller B1 Steam gun B2 Unlocking button B3 Selector switch for the steam volume with child protection B4 Steam lever B5 Steam hose A11 A6 A12 ...

Page 9: ... C1 Detail nozzle C2 Round brush D1 Hand nozzle D2 Manual nozzle microfibre cover E1 Extension tubes two tubes E2 Unlocking button F1 Floor nozzle F2 Hook and loop fastener F3 Microfibre floor cloth F4 Carpet glider G1 Descaler F4 G1 ...

Page 10: ... water 2 Screw in safety cap 3 Plug in the mains plug Turn on the machine The green and orange indicator lamps light up 4 Wait until the orange indicator lamp goes out 5 Connect the accessories to the steam gun The steam cleaner is ready to use Quick Reference 6 5 min 1 liter click ...

Page 11: ... switch to the required steam volume While operating the steam switch always direct the steam gun at a separate piece of cloth until the steam is emitted evenly Note The heating of the steam cleaner is turned on in regular intervals during the operation of the appli ance in order to maintain the pressure in the boiler at a constant level When the heating is turned on the orange indicator lamp heat...

Page 12: ...ly suit ed for cleaning difficult access locations joints fittings drains sinks toilets blinds and heaters Heavy lime scale can be drenched in vinegar prior to steam clean ing Let the vinegar penetrate for about 5 minutes Illustration Slide the spotlight nozzle onto the steam gun The round brush can be installed onto the detail nozzle as an accessory Attached brushes can therefore be used to remov...

Page 13: ...cleaning the carpet 몇 CAUTION Beware of burns to your feet The carpet glider can heat up during the steaming pro cess Do not operate or remove the carpet glider bare footed or using open sandals Only operate or remove the carpet glider using suitable footwear Illustration Press the strap on the carpet glider downwards us ing your toecap Lift the floor nozzle upwards Rinse the steam cleaner boiler ...

Page 14: ...ce Refill water Steam switch is secured with the lock child proof lock Move the selector switch for the steam volume to the front Press the steam gun until less water is emitted Descale the steam boiler Subject to technical modifications Care of the Accessories Troubleshooting Long heating up time Steam boiler is decalcified No steam No water in the steam boiler Steam lever cannot be pressed anymo...

Page 15: ......

Page 16: ...www kaercher com dealersearch Alfred Kärcher 6 Co KG Alfred Kärcher Str 28 40 71364 Winnenden Germany Tel 49 7195 14 0 Fax 49 7195 14 2212 ...

Reviews: