background image

English

7

these operating instructions. Detergents are not re-
quired. Observe the safety instructions.

Environmental protection

The packing materials can be recycled. Please 
dispose of packaging in accordance with the en-
vironmental regulations.
Electrical and electronic appliances contain valu-
able, recyclable materials and often components 
such as batteries, rechargeable batteries or oil, 
which - if handled or disposed of incorrectly - can 

pose a potential threat to human health and the environ-
ment. However, these components are required for the 
correct operation of the appliance. Appliances marked 
by this symbol are not allowed to be disposed of togeth-
er with the household rubbish.

Notes on the content materials (REACH)

Current information on content materials can be found 
at: 

www.kaercher.com/REACH

Accessories and spare parts

Only use original accessories and original spare parts. 
They ensure that the appliance will run fault-free and 
safely.
Information on accessories and spare parts can be 
found at 

www.kaercher.com

.

Scope of delivery

The scope of delivery for the appliance is shown on the 
packaging. Check the contents for completeness when 
unpacking. If any accessories are missing or in the 
event of any shipping damage, please notify your deal-
er.

Warranty

The warranty conditions issued by our relevant sales 
company apply in all countries. We shall remedy possi-
ble malfunctions on your appliance within the warranty 
period free of cost, provided that a material or manufac-
turing defect is the cause. In a warranty case, please 
contact your dealer (with the purchase receipt) or the 
next authorised customer service site.
(See overleaf for the address)

Safety devices

CAUTION

Missing or modified safety devices

Safety devices are provided for your own protection.
Never modify or bypass safety devices.

Symbols on the device

(according to type of appliance)

Pressure controller

The pressure controller keeps the pressure in the steam 
boiler as constant as possible during operation. The 
heating is switched off when the maximum operating 
pressure is reached in the steam boiler and is activated 

if there is a pressure drop in the steam boiler as a result 
of a steam removal.

Safety thermostat

The safety thermostat prevents the device from over-
heating. If the pressure regulator and the boiler thermo-
stat fail and the unit overheats, the safety thermostat 
switches the unit off. Before resetting of the safety ther-
mostat, contact the responsible KÄRCHER Customer 
Service.

Boiler thermostat

The boiler thermostat switches off the heating in the event 
of a fault; for example, if there is no water in the steam boil-
er and the temperature in the steam boiler rises.
As soon as you refill the water, the device is ready for 
use again.

Maintenance lock

The maintenance lock seals the steam boiler from the 
steam pressure present. The maintenance cap is also a 
pressure relief valve. If the pressure regulator is defec-
tive and the steam pressure in the steam boiler rises, 
the pressure relief valve opens and steam is escapes 
through the lock.
Prior to restarting the device, contact the responsible 
KÄRCHER Customer Service.

Description of the device

The maximum amount of equipment is described in 
these operating instructions. Depending on the model 
used, there are differences in the scope of delivery (see 
packaging).

For the illustrations, refer to the graphics page.
Illustration A

1

Device socket with cover

2

Water reservoir

3

Carrying handle for the water reservoir

4

Selector switch

5

Control panel

6

Display - OFF position

7

Display - water shortage (red)

8

Display - heating (green)

9

Min. steam stage

10

Steam setting selection range

11

Max. steam stage

12

VapoHydro function steam stage

13

Cap for accessory compartment

14

Maintenance lock

15

Carrying handle

16

Holder for accessories

17

Accessory storage compartment

18

Mains connection cable storage compartment

19

Park bracket for floor nozzle

20

Mains connection cable with mains plug

21

Non-driven wheels (2 x)

Risk of burns, surface of appliance be-
comes hot during operation

Risk of scalding from steam

Read operating instructions

Summary of Contents for SC 5 EasyFix Iron Plug

Page 1: ...SC 5 EasyFix Iron Plug SC 5 EasyFix Iron 59682880 10 22...

Page 2: ...1 2 3 4 5 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 16 19 20 21 22 23 24 25 26 27 28 33 38 39 29 30 34 35 36 37 42 40 41 31 32 46 45 43 44 A 2...

Page 3: ...B C D E F G H 1 2 I J K L M 3...

Page 4: ...N 1 2 O P Q R S 4...

Page 5: ...he mains power Use a receptacle for fill ing Do not use the d in swimming pools which contain water The mains plug and extension cable connec tion must not be in water Do not clean over floor sockets...

Page 6: ...rvice CAUTION Have repair work carried out by the authorised customer service only ATTENTION Do not fill with any cleaning agents or other supplements Do not use vinegar or similar agents Descaling th...

Page 7: ...oiler as constant as possible during operation The heating is switched off when the maximum operating pressure is reached in the steam boiler and is activated if there is a pressure drop in the steam...

Page 8: ...l the parts apart Illustration O Operation Filling water The water reservoir can be removed at any time for fill ing or be filled directly at the device ATTENTION Damage to the device Unsuitable water...

Page 9: ...partment 7 Open the maintenance lock To do this place the open end of an extension tube on the maintenance lock insert this into the guide so it engages and open it Illustration R 8 Fill the steam boi...

Page 10: ...s during steam cleaning which will disappear however once these have been used several times We recommend sweeping the floor or vacuum cleaning it before using the device In this way the floor will be...

Page 11: ...ner 2 Insert the steam plug of the iron into the unit plug un til it clicks into place 3 Putting the steam cleaner into operation see chap ter Switching on the device 4 Wait until the steam cleaner is...

Page 12: ...e washing tag Do not use any liquid softeners as this will affect the ability of the cloths to pick up dirt 1 Wash the floor cleaning cloths and covers at a max temperature of 60 C in the washing mach...

Page 13: ...mance data Heating capacity W 2200 Heating capacity of iron W 700 Maximum operating pressure MPa 0 42 Heating up time Minutes 3 Continuous steaming g min 60 Maximum steam blast g min 150 VapoHydro ste...

Page 14: ......