background image

English

 13

Note: 

Even if you iron without steam, there 

must be water in the boiler.

Adjust the temperature of the iron ac-
cording to the garment you want to iron.

Note:

 Please observe the ironing and 

washing instructions in your garment

.

As soon as the indicator lamp of the 
heater of the iron switches off, you can 
start ironing. 

Danger

Always disconnect the mains plug and al-
low the steam cleaner to cool down before 
performing any maintenance work.

Rinse the steam cleaner boiler at the latest 
after 10 boiler fillings. 

Disconnect the mains plug from the 
socket.

Allow the steam cleaner to cool down.

Empty the water reservoir.

Remove the accessories from the ac-
cessory compartments.

Illustration 

Open the locking door of the accessory 
compartment.

Remove the accessories from the ac-
cessory compartment.

Open the maintenance lock. For this, 
place the open end of an extension pipe 
onto the maintenance lock, lock it into 
the guide and unscrew it.

Fill the boiler with water and shake it 
strongly. This dissolves lime scaling re-
siding on the boiler bottom. 

Completely empty the steam boiler to 
remove existing water (see fig.  ).

As limes cale builds up on the boiler walls, 
we recommend to de scale the boiler in the 
following intervals (RF = reservoir fillings):

Note:

 Please contact your Conservancy 

Board or the local water supply company to 
inquire about the hardness of your water.

Disconnect the mains plug from the 
socket.

Allow the steam cleaner to cool down.

Empty the water reservoir.

Remove the accessories from the ac-
cessory compartments.

Illustration 

Open the locking door of the accessory 
compartment.

Remove the accessories from the ac-
cessory compartment.

Open the maintenance lock. For this, 
place the open end of an extension pipe 
onto the maintenance lock, lock it into 
the guide and unscrew it.

Completely empty the steam boiler to 
remove existing water (see fig.  ).

Warning

Only use products approved by KÄRCHER 
to exclude any damages of the appliance.

User the KÄRCHER decalcifier sticks 
(order no. 6.295-047) to decalcify the 
water. Please follow the dosing instruc-
tions on the packaging while using the 
decalcifying solution.

Caution

Use caution when filling and emptying the 
steam cleaner. The descaling solution can 
have an aggressive effect on delicate sur-
faces.

Pour the descaling solution into the boil-
er and allow it to react for approximately 
8 hours.

Dry ironing

Synthetics

•• Wool, silk
••• Cotton, linen

Maintenance and care

Rinsing the steam boiler

Descaling the steam boiler

Degree of hard-
ness

° dH

mmol/l

RF

I

soft

0-  7  0-1,3

100

II medium

7-14

1,3-2,5

90

III hard

14-21 2,5-3,8

75

IV very hard

>21

>3,8

50

Summary of Contents for SC 4.100 CB

Page 1: ...59645060 09 12 SC 4 100 CB Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them...

Page 2: ...2 Quick reference...

Page 3: ...3...

Page 4: ...4...

Page 5: ...ems Notes about the ingredients REACH You will find current information about the ingredients at www kaercher com REACH The scope of delivery of your appliance is il lustrated on the packaging Check t...

Page 6: ...ation Warning The appliance may only be connected to an electrical supply which has been installed in accordance with IEC 60364 The appliance may only be connected to alternating current The voltage m...

Page 7: ...mum operating pressure of 4 bar is reached in the boiler and is reactivated in case of a pressure drop in the boiler due to steam tapping If in case of a malfunction there is no wa ter in the boiler t...

Page 8: ...utton of the steam gun locks into place Illustration Use the extension tubes if necessary To do so connect one or both exten sion tubes to the steam gun Insert the required accessories on the free end...

Page 9: ...ch to turn on the appliance Indicator lamp heating on is blinking green Note If there is no or not enough water in the steam boiler the water pump starts and supplies water from the reservoir into the...

Page 10: ...r This way the floor is already cleared of dirt loose particles prior to the wet cleaning Prior to treatment with the steam cleaner always check the reaction of the textiles in an inconspicuous locati...

Page 11: ...the terry cloth cover over the hand noz zle Especially well suited for small washa ble areas shower stalls and mirrors Suited for all washable walls and floor cov erings e g stone floors tiles and PV...

Page 12: ...udibly Make sure that there is fresh tap water in the boiler of the steam cleaner Start up the steam cleaner according to the description Wait until the steam cleaner is ready to use All fabrics can b...

Page 13: ...the following intervals RF reservoir fillings Note Please contact your Conservancy Board or the local water supply company to inquire about the hardness of your water Disconnect the mains plug from th...

Page 14: ...ized customer service Danger Always disconnect the mains plug and al low the steam cleaner to cool down before performing any maintenance work Repair works may only be performed by the authorized cust...

Page 15: ...cifications Electrical connection Voltage 220 240 V 1 50 60 Hz Protection class IPX4 Protective class I Performance data Heating output 1800 W Heating output steam iron 700 W Operating pressure max 0...

Page 16: ...70 990 5 covers made of cotton Round brush kit 2 863 058 4 round brushes for the detail nozzle Round brush kit with brass bristles 2 863 061 Removal of especially stubborn dirt ideal for insensitive s...

Page 17: ......

Page 18: ...www karcher co nz www karcher com au...

Reviews: