background image

10

Safety

Grounding Instructions

THIS PRODUCT IS FOR COMMERCIAL USE
ONLY.

Electrical:

In the USA  this machine operates on a standard 15 
amp 115V, 60 hz,  A.C. power circuit . The amp,  
hertz, and voltage are listed on the data label found 
on each machine.  Using voltages above or below 
those indicated on the data label will cause serious 
damage to the motors. 

Extension Cords:

If an extension cord is used, the wire size must be at 
least one size larger than the power cord on the 
machine, and must be limited to 50 feet (15.5m) in 
length.

Grounding Instructions:

This appliance must be grounded.  If it should 
malfunction or break down, grounding provides a 
path of least resistance for electric current to reduce 
the risk of electric shock.  This appliance is equipped 
with a cord having an equipment-grounding 
conductor and grounding plug.  The plug must be 
inserted into an appropriate outlet that is properly 
installed and grounded in accordance with all local 
codes and ordinances. 

This appliance is for use on a nominal 120-volt circuit, 
and has a grounded plug that looks like the plug in 
“Fig. A”.  A temporary adaptor that looks like the 
adaptor in “Fig . C”  may be used to connect this plug 
to a 2-pole receptacle as shown in “Fig. B”, if a 
properly grounded outlet is not available.  The 
temporary adaptor should be used only until a 
properly grounded outlet (Fig. A) can be installed by a 
qualified electrician.  The green colored rigid ear, lug, 
or  the like extending from the adaptor must be 
connected to a permanent ground such as a properly 
grounded outlet box cover.  Whenever the adaptor is 
used, it must be held in place by a metal screw.

Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. 
Check with a qualified electrician or service 
person if you are in doubt as to whether the outlet 
is properly grounded. Do not modify the plug 
provided with the appliance - if it will not fit the 
outlet, have a proper outlet installed by a 
qualified electrician. Use only GFCI protected 
receptacles.

Une connexion non conforme du conducteur de 
mise à la terre de l’appareil peut provoquer une 
dé charge électrique. Consulter un électricien 
qualifié ou une personne du service aprés vente 
si vous suspectez que la prise de courant n’est 
pas correctement mise à la terre. Ne pas modifier 
la fiche fournie avec l’appareil - si elle ne rentre 
pas dans la prise, faites installer une prise appr-
ropriée par un électricien qualifié. Utilisez-le 
uniquement sur des réceptacles protégés GFCI.

86401130 Operator’s Manual - Apache 115V

Summary of Contents for Prochem Apache 115V

Page 1: ...86401130 A 06 22 15 Apache 115V Air Mover Operating instructions ENG MODELS 1 004 051 0 From Serial Number Ref No1 See Serial Number Page in Spare Parts List or call manufacturer ...

Page 2: ...ster your product go to http www prochem com WarrantyRegistration aspx For customer assistance 1 800 444 7654 86401130 Operator s Manual Apache 115V Machine Data Label Overview The Apache Air Mover is intended for professional disaster restoration and remediation but can also be used for carpet cleaning construction and janitorial sanitation professionals in general ventilating and structural dryi...

Page 3: ...ow To Use This Manual 4 Safety IMPORTANT SAFETY INSTRUCTIONS 5 CONSIGNES DE SÉCURITÉ IMPORTANTES 6 HAZARD INTENSITY LEVEL 7 Safety Labels 9 Grounding Instructions 10 Machine Operation Maintenance On Off Procedure 11 Power Cord switch 11 86401130 Operator s Manual Apache 115V ...

Page 4: ...t information regarding hazardous or unsafe practices of the machine Levels of hazards are identified that could result in product damage personal injury or severe injury resulting in death The OPERATIONS section is to familiarize the operator with the operation and function of the machine The MAINTENANCE section contains preventive maintenance to keep the machine and its compo nents in good worki...

Page 5: ...pairs must be done by qualified personnel The machine shall only be operated by instructed and authorized persons Do not handle the plug or machine with wet hands Do not unplug machine by pulling on cord To unplug grasp the plug not the cord Do not use with damaged cord or plug Do not pull or carry by cord use cord as a handle run over cord close a door on cord or pull cord around sharp edges or c...

Page 6: ...é L utilisation de l appareil est exclusivement réservé à des personnes formées et autorisées Ne manipulez pas la fiche ou l appareil les mains mouillées Ne débranchez pas l appareil en tirant sur le cordon Pour le débrancher empoignez la fiche non pas le cordon N utilisez pas l appareil si le cordon ou la fiche est endommagé e Observez toutes les consignes figurant dans ce manuel au sujet de la m...

Page 7: ... machine damage or faulty operation immediately Do not use the machine if it is not in proper operating condition Following is information that signals some potentially dangerous conditions to the operator or the equipment Read this information carefully Know when these conditions can exist Locate all safety devices on the machine Please take the necessary steps to train the machine operating pers...

Page 8: ...une détérioration de la machine Ne pas utiliser la machine si celle ci ne fonctionne pas correctement Lire soigneusement les informations ci dessous signalant certains dangers potentiels pour l opérateur de la machine L opérateur doit être absolument au courant de ces dangers potentiels Localiser tous les dispositifs de sécurité sur la machine Il est conseillé de prendre les mesures nécessaires po...

Page 9: ... become illegible promptly replace them Emplacement De L étiquette De Sécurité REMARQUE Ces dessins indiquent l emplacement des étiquettes de sécurité sur la machine Si à tout moment les étiquettes deviennent illisibles contactez votre représentant autorisé pour un remplacement rapide 86401130 Operator s Manual Apache 115V ...

Page 10: ...this plug to a 2 pole receptacle as shown in Fig B if a properly grounded outlet is not available The temporary adaptor should be used only until a properly grounded outlet Fig A can be installed by a qualified electrician The green colored rigid ear lug or the like extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adaptor ...

Page 11: ...s répa rations ou des ajustements de la machine Power Cord switch Power cord and switch can be serviced 1 Remove the 4 screws holding switch down 2 To replace switch unplug wires and replace switch See wiring diagram 3 To replace power cord see step 1 4 Unplug wires loosen strain relief and remove cord 5 Replace power cord See wiring diagram When reinstalling electrical parts refer to wiring diagr...