![Kärcher NT68/1 Operating Instructions Manual Download Page 12](http://html2.mh-extra.com/html/karcher/nt68-1/nt68-1_operating-instructions-manual_3572612012.webp)
98013230 WET DRY VACUUM
12
Safety
ELECTRICAL:
In the USA this machine operates on a standard 15
amp 115V, 60 hz, A.C. power circuit. The amp, hertz,
and voltage are listed on the data label found on each
machine. Using voltages above or below those indi-
cated on the data label will cause serious damage to
the motors.
EXTENSION CORDS:
If an extension cord is used, the wire size must be
at least one size larger than the power cord on the
machine, and must be limited to 50 feet (15.5m) in
length.
GROUNDING INSTRUCTIONS:
This appliance must be grounded. If it should mal-
function or break down, grounding provides a path of
least resistance for electric current to reduce the risk
of electric shock. This appliance is equipped with a
cord having an equipment-grounding conductor and
grounding plug. The plug must be inserted into an ap-
propriate outlet that is properly installed and grounded
in accordance with all local codes and ordinances.
This appliance is for use on a nominal 120-volt circuit,
and has a grounded plug that looks like the plug in
“Fig. A”. A temporary adaptor that looks like the adap-
tor in “Fig. C” may be used to connect this plug to a
2-pole receptacle as shown in “Fig. B”, if a properly
grounded outlet is not available. The temporary adap-
tor should be used only until a properly grounded out-
let (Fig. A) can be installed by a qualifi ed electrician.
The green colored rigid ear, lug, or wire extending
from the adaptor must be connected to a permanent
ground such as a properly grounded outlet box cov-
er. Whenever the adaptor is used, it must be held in
place by a metal screw.
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock.
Check with a qualifi ed electrician or service person if
you are in doubt as to whether the outlet is properly
grounded. Do not modify the plug provided with the
appliance - if it will not fi t the outlet, have a proper
outlet installed by a qualifi ed electrician.
Le raccordement incorrect du conducteur de
terre d’équipement peut entraîner des risques
d’électrocution. Vérifi ez auprès d’un électricien quali-
fi é ou d’un responsable de l’entretien si vous avez
quelque doute que ce soit quant au raccordement à
la terre de votre prise murale. Ne modifi ez pas la fi che
fournie avec l’appareil : si elle ne correspond pas à la
prise murale, faites installer une prise adéquate par
un électricien qualifi é.
USING AN ADAPTOR
GROUNDING CONNECTION
Outlet
FIGURE A
Grounded
Grounding Pin
Metal Screw
Adaptor
FIGURE B
Grounded
Outlet Box
Screw
Adaptor
FIGURE C
Tab for Grounding
Note: Adaptors are not allowed in Canada.
AVERTISSEMENT
Summary of Contents for NT68/1
Page 5: ...98013230 WET DRY VACUUM 5 Notes...
Page 13: ...98013230 WET DRY VACUUM 13 Notes...
Page 23: ...98013230 ASPIRADORA DE RESIDUOS S LIDOS Y L QUIDOS 23 Notas...
Page 28: ...98013230 ASPIRADORA DE RESIDUOS S LIDOS Y L QUIDOS 28 Notas...
Page 34: ...98013230 WET DRY VACUUM 34 Handle Manija 1 2 3 4 5 6 7 8 10 17 12 13 14 15 16 13 16 13 9 13 11...
Page 40: ...98013230 WET DRY VACUUM 40 9 1 2 3 4 5 7 8 9 10 15 14 11 12 13 15 16 17 6 Tank Dep sito...
Page 46: ...98013230 WET DRY VACUUM 46 1 2 3 4 5 6 7 8 9 4 8 Wheels Ruedas...
Page 51: ...98013230 WET DRY VACUUM...