– 5
몇
Warning
Crush hazard. Never hold your
hands between the dirt contain-
er and the intermediate ring or
put them near the lifting mecha-
nism while locking. Lock the container by
actuating the bow of the placement me-
chanics with both hands.
Release and remove the suction head.
Clean the electrodes as well as the
space between the electrodes with a
brush.
Clean electrode extensions by means
of a brush.
Insert and lock the suction head.
Danger
First pull out the plug from the mains before
carrying out any tasks on the machine.
Check the receptacle and the fuse of
the power supply.
Check the power cable, the power plug,
the electrodes and the electrode exten-
sions of the device.
Turn on the appliance.
Empty the container.
Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
Clean the electrodes as well as the
space between the electrodes with a
brush.
Clean electrode extensions by means
of a brush.
Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
Replace the filled disposal bag (option).
Ensure the filter cover properly locks
into place.
Replace the flat pleated filter.
Check for proper installation of the flat
pleated filter.
Replace the flat pleated filter.
Clean the electrodes as well as the
space between the electrodes with a
brush.
Clean electrode extensions by means
of a brush.
Continuously check the filling level in
case of non-conductive liquid.
Suction hose is not connected.
Inform Customer Service
Inform Customer Service
Clean electrodes and electrode
extensions
Troubleshooting
Suction turbine does not run
Suction turbine turns off
Suction turbine does not start again
after the container has been
emptied
Suction capacity decreases
Dust comes out while vacuuming
Automatic shut-off (wet vacuum
cleaning) does not react
Automatic filter cleaning is not
working
Automatic filter cleaning cannot be
switched off
Automatic filter cleaning cannot be
switched on
17